2016
DOI: 10.1016/j.icheatmasstransfer.2016.04.003
|View full text |Cite
|
Sign up to set email alerts
|

The experimental study on the heat transfer and friction factor characteristics in tube with a new kind of twisted tape insert

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0
2

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(9 citation statements)
references
References 19 publications
0
7
0
2
Order By: Relevance
“…Dengan menggunakan prinsip kekekalan energi antara fluida panas yang masuk dan keluar dengan laju perpindahan panas, laju panas dapat dihitung menggunakan Persamaan (6). (6) dimana adalah laju masa fluida masuk pipa, c p adalah panas jenis pada tekanan konstan dan T in serta T out berturutturut adalah temperatur fluida masuk dan keluar. Laju masa fluida masuk pipa ditentukan dengan menggunakan Persamaan (7).…”
Section: Gambar 2 Geometri Control Volume Dari Domain Komputasiunclassified
See 1 more Smart Citation
“…Dengan menggunakan prinsip kekekalan energi antara fluida panas yang masuk dan keluar dengan laju perpindahan panas, laju panas dapat dihitung menggunakan Persamaan (6). (6) dimana adalah laju masa fluida masuk pipa, c p adalah panas jenis pada tekanan konstan dan T in serta T out berturutturut adalah temperatur fluida masuk dan keluar. Laju masa fluida masuk pipa ditentukan dengan menggunakan Persamaan (7).…”
Section: Gambar 2 Geometri Control Volume Dari Domain Komputasiunclassified
“…Karakteristik perpindahan panas dan gesekan di dalam pipa dengan sisipan plat terpuntir yang baru diperkenalkan oleh Changzhong Man dkk. melalui kaji eksperimental [6]. Mereka meneliti efek sisipan plat terpuntir yang baru dengan beberapa perbedaan panjang plat terhadap perpindahan panas dan gesekan.…”
unclassified
“…Esmaeilzadeh et al [20] experimentally revealed that the twisted tape inserts can markedly improve the convective heat transfer of the circular tube. Man et al [21] experimentally studied the heat transfer performance of a twisted tape insert and found that both Nu and f increased significantly.…”
Section: Introductionmentioning
confidence: 99%
“…These studies were performed either numerically or experimental or both of them. The thermo-hydraulic characteristics of TT engaged tubes were investigated based on different insert properties to analyze the effects of such as twist ratio [4,5], clockwise−counterclockwise arrangement [6,7], cross hollow TT [8], spirally grooved tube [9], spirally grooved tube with overlapped large/small twin TTs [10], two-phase flow [11], V-cut TT [12], coupling of TT with WC [13,14], twin-counter/co-swirl tape [15], double counter TT [16], triple TT [17], and quadruple TT [18].…”
Section: Introductionmentioning