2021
DOI: 10.1016/j.dyepig.2021.109407
|View full text |Cite
|
Sign up to set email alerts
|

The effects of the composition and structure of quantum dots combined with cobalt phthalocyanine and an aptamer on the electrochemical detection of prostate specific antigen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 58 publications
0
6
0
Order By: Relevance
“…Therefore, the optimum operation and minimal interference in mixed samples are evidenced by the outstanding performance of all sensors manufactured with the NGQDs‐based aptasensor. Similar to the concentration of PSA in buffer (0.044 ng/mL), the LOD was determined to be 0.043 ng/mL in men with prostate cancer, 104 which is still below the cutoff value (4 ng/mL) in these patients 105 …”
Section: Qd‐apt Conjugates For Cancer Managementmentioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, the optimum operation and minimal interference in mixed samples are evidenced by the outstanding performance of all sensors manufactured with the NGQDs‐based aptasensor. Similar to the concentration of PSA in buffer (0.044 ng/mL), the LOD was determined to be 0.043 ng/mL in men with prostate cancer, 104 which is still below the cutoff value (4 ng/mL) in these patients 105 …”
Section: Qd‐apt Conjugates For Cancer Managementmentioning
confidence: 99%
“…The arrow indicates an increase in PSA concentrations. 104 DOX QD-Apt. 37 Therefore, it can be applied to imaging prostate cancer cells and simultaneously deliver chemotherapeutic agents to these cells.…”
Section: ) (C) This Model Is Based Onmentioning
confidence: 99%
See 1 more Smart Citation
“…The literature shows that GQDs are a great platform for the specific and sensitive recognition of biomarkers, which are highly synergistic with electrochemical sensors. 303 Recently Nxele et al developed an aptasensor for the electrochemical detection of the prostate specific antigen (PSA) using different combinations of aptamer, CoPc, and GQD modified on a glass carbon electrode (GCS). The best efficacy was obtained by the GCE-GQD-CoPc (π-π)-aptamer with an LOD of 3.66 pM determined by electrochemical impedance spectroscopy (EIS) and 0.66 pM by differential pulse voltammetry (DPV).…”
Section: Biomaterials Science Reviewmentioning
confidence: 99%
“…In recent works, exciting applications surrounding QDs have also been conducted. Due to their outstanding optical properties, QDs can be used for cancer cell imaging [39,40]. A review article on biomedical and drugs administration mediated by QDs was developed in [41].…”
Section: Introductionmentioning
confidence: 99%