2004
DOI: 10.1134/1.1646718
|View full text |Cite
|
Sign up to set email alerts
|

The effects of temporal and longitudinal spatial coherence in a disbalanced-arm interferometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…For biomedical optics applications the use of infrared light is preferable as it penetrates deeper in tissue [90], which then requires the development of highresolution infrared cameras. For frequency-domain FF-OCT operation [91], tunable sources and fs sources that can reveal the spectral interference images in a short time will be helpful.Finally, it should be mentioned that spatial coherence effects in other related fields such as interferometry in general, holography, surface profiling and other applications has been an active field of research during the last two decades [92][93][94][95][96][97]. The group at Saratov University has been studying longitudinal spatial coherence extensively [98][99][100][101] …”
Section: Conclusion and Future Trendsmentioning
confidence: 99%
“…For biomedical optics applications the use of infrared light is preferable as it penetrates deeper in tissue [90], which then requires the development of highresolution infrared cameras. For frequency-domain FF-OCT operation [91], tunable sources and fs sources that can reveal the spectral interference images in a short time will be helpful.Finally, it should be mentioned that spatial coherence effects in other related fields such as interferometry in general, holography, surface profiling and other applications has been an active field of research during the last two decades [92][93][94][95][96][97]. The group at Saratov University has been studying longitudinal spatial coherence extensively [98][99][100][101] …”
Section: Conclusion and Future Trendsmentioning
confidence: 99%
“…The effect of an optically thick film positioned along the light path of one of the interferometer arms was experimentally investigated by Ryabukho et al 9 Their investigation is extended here, and adapted to our setup, so we may rigorously explain the effect of the additional medium in one of the arms on the longitudinal coherence function. Introducing a uniform dielectric medium into one of the interferometer arms shifts the front focal point of lens L 1 forward along this arm relative to the focal point in the other arm.…”
Section: Longitudinal Spatial Coherence In the Presence Of A Partiallmentioning
confidence: 92%
“…As we shall see next, this phenomenon causes the spatial longitudinal coherence function to shift in the direction opposite that of the temporal coherence function, although both functions are shifted because of the same dielectric medium. 9 The two complex amplitudes at the sample and the reference arms, which originated from the same source point, interfere coherently. However, the contributions from all other source points are summed incoherently because of the incoherent nature of the source.…”
Section: Longitudinal Spatial Coherence In the Presence Of A Partiallmentioning
confidence: 99%
“…Spatial coherence profilometry shows an opposite effect. A plate of glass appears to shorten the interferometer arm [8]. The mirror in this arm must be shifted away from the beam splitter to balance the interferometer again.…”
Section: Influence Of Dispersionmentioning
confidence: 99%