1991
DOI: 10.1016/0167-8140(91)90049-m
|View full text |Cite
|
Sign up to set email alerts
|

The effect on minimum tumor dose of restricting target-dose inhomogeneity in optimized three-dimensional treatment of lung cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

1995
1995
2017
2017

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…A similar effect on minimum tumor dose can be seen when the dose homogeneity limit for the target is varied. 50 The small variations in the dose specifications that induce these large changes in minimum tumor dose fall well within the range of uncertainty in current estimates of the dose distributions. The tolerance limits themselves can become better refined by allowing better correlations between dose and adverse events in large scale clinical trials, a research topic which would benefit from improved support.…”
Section: A How Will Improved Accuracy Be Used By the Clinic?mentioning
confidence: 53%
“…A similar effect on minimum tumor dose can be seen when the dose homogeneity limit for the target is varied. 50 The small variations in the dose specifications that induce these large changes in minimum tumor dose fall well within the range of uncertainty in current estimates of the dose distributions. The tolerance limits themselves can become better refined by allowing better correlations between dose and adverse events in large scale clinical trials, a research topic which would benefit from improved support.…”
Section: A How Will Improved Accuracy Be Used By the Clinic?mentioning
confidence: 53%
“…A minimum tumor dose of Ͼ80 Gy could be delivered in all six cases examined when an inhomogeneity limit of 20% was accepted, but the minimum tumor dose fell to the range 44 -64 Gy when the limit was tightened to 13%-17%. 125 An example of the differences that can be seen in the sensitivity of tumor dose to various tissue limits is shown in Fig. 8 for a hypothetical model.…”
Section: Mark Langermentioning
confidence: 99%
“…Unfortunately, the external radiation dose cannot generally exceed 60 Gy due to the tolerance limits of normal lung tissue. However, 60 Gy is a dose that is not sufficient for tumor eradication ( 14 ). The pulmonary volume of the patients was reduced following the operation, resulting in poor pulmonary function.…”
Section: Discussionmentioning
confidence: 99%