The Effect of Titanium Implant Abutment Surface Irregularities on Plaque Accumulation In Vivo

Abstract: The purpose of this study was 2-fold to: 1) evaluate in vitro the surface texture of titanium implant abutments after exposure to plastic scalers, an air-powder abrasive system, rubber cup polishing with flour of pumice, and untreated control abutments; and 2) compare plaque accumulation in humans on abutments treated with the above methods. In part I, 5.5 mm abutments were instrumented for 30 seconds per 90 degrees segment with the respective methods. The surface character was compared to untreated controls u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
43
0
4

Year Published

2003
2003
2016
2016

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 61 publications
(55 citation statements)
references
References 7 publications
2
43
0
4
Order By: Relevance
“…Some studies have shown that AP does not alter the physical structure of some implant surfaces, [22, 23] but others have shown that it could largely obliterate the milling marks and cause some surface pitting and irregular crater-like defects [24]. These changes are time dependent, in all specimens, a 5-second exposure did not induce deep changes in the surfaces but a 15-second exposure modified all the specimen surfaces [23].…”
Section: Resultsmentioning
confidence: 99%
“…Some studies have shown that AP does not alter the physical structure of some implant surfaces, [22, 23] but others have shown that it could largely obliterate the milling marks and cause some surface pitting and irregular crater-like defects [24]. These changes are time dependent, in all specimens, a 5-second exposure did not induce deep changes in the surfaces but a 15-second exposure modified all the specimen surfaces [23].…”
Section: Resultsmentioning
confidence: 99%
“…RE-SULTADOS: não foram encontradas diferenças significativas na morfologia entre os grupos (pϾ0,05) entretanto, o grupo de controle apresentou uma quantidade de células significativamente maior (71,44 ϩ/-31,93, média ϩ/-s.d.) em comparação com o grupo com tratamento (35,31 ϩ/-28, 14), conforme indicado por um teste t sem paridade (pϭ0,001). CONCLUSÃO: a utilização do sistema profilático de jato de areia na superfície dos pivôs de cicatrização de titânio reduziram a proliferação das células mas não influenciaram a morfologia da célula.…”
Section: Disclosureunclassified
“…Ti as implant is problematic as long as it presents low wear resistance 5,6 . A crucial issue concerning the removal of the bacterial plaque from the transmucous dental implant cylinders is the possibility of damage by the routine instruments, such as stainless steel Gracey scaler, sonic and ultrasonic apparatus [7][8][9][10] . Such an obstacle has been bypassed using mild instrumental, but the results are not satisfactory.…”
Section: Introductionmentioning
confidence: 99%