2007
DOI: 10.1016/j.tripleo.2006.12.026
|View full text |Cite
|
Sign up to set email alerts
|

The effect of thermal treatment on the resistance of nickel-titanium rotary files in cyclic fatigue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
70
0
4

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 81 publications
(77 citation statements)
references
References 13 publications
3
70
0
4
Order By: Relevance
“…DSC curves were very complex with irregular peaks. These results were also confirmed by other studies (28,32). Therefore, the manufacturer must perform an appropriate heat treatment, which will be accompanied by beneficial changes in mechanical properties and improved clinical performance.…”
Section: Metallurgical Characterization Of Thermomechanically-treatedsupporting
confidence: 82%
See 1 more Smart Citation
“…DSC curves were very complex with irregular peaks. These results were also confirmed by other studies (28,32). Therefore, the manufacturer must perform an appropriate heat treatment, which will be accompanied by beneficial changes in mechanical properties and improved clinical performance.…”
Section: Metallurgical Characterization Of Thermomechanically-treatedsupporting
confidence: 82%
“…Four methods (13) have been used to investigate in vitro fatigue fracture resistance of NiTi rotary endodontic instruments: (1) curved metal tube (49), (2) grooved block-and-rod assembly (54-60), (3) rotation against an inclined plane (61, 62), and (4) 3-point bend of a rotating instrument (32,63,64). However, in an effort to understand the nature of the metal alterations and their impact on enhancing resistance to fatigue in particular, an international standard for cyclic fatigue testing of NiTi rotary instruments should be developed in order to ensure the uniformity of methodologies so that the resulting data can be compared (15).…”
Section: Fatigue Propertiesmentioning
confidence: 99%
“…Some authors relate instrument fracture to fatigue caused by repetitive bending stresses on curved canals. 11,12 Others indicate torsion as the primary mechanism responsible for fracture. 13 Torsion can be generated when the rotary file is obstructed against the canal wall or exposed to excessive pressure by the clinician.…”
Section: Discussionmentioning
confidence: 99%
“…Twisted method was introduced as one of the manufacturing methods that can increase the fatigue resistance of end product in comparison to the traditional grinding process (10). Other investigators reported that thermal treatments such as annealing of these instruments can enhance their fatigue resistance (11). Apart from reasons mentioned for the fatigue failure of NiTi instruments, others have suggested that the corrosion mechanisms, as a result of chemomechanical preparation and chemical disinfection or sterilisation, might be an initial factor for fatigue failure.…”
Section: Highlightsmentioning
confidence: 99%