2016
DOI: 10.1016/j.jtice.2016.01.001
|View full text |Cite
|
Sign up to set email alerts
|

The effect of surface morphology and treatment of Fe 3 O 4 nanoparticles on the corrosion resistance of epoxy coating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
24
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 71 publications
(27 citation statements)
references
References 41 publications
0
24
0
Order By: Relevance
“…As it can be seen in this Figure, the FTIR spectra of CdSe/ZnS-OLA showed a sharp peak at 3744 cm -1 , which is related to the stretching vibration of N-H bonds, indicating that the NH 2 -containing ligand was adsorbed on the synthesized QD surface [ 63 ] . The broad absorption peak at about 3200-3600 cm -1 can be assigned to the –OH stretching vibration of physically adsorbed water molecules in CdSe/ZnS and CdSe/ZnS-MPA samples [ 64 ] . The significant reduction of the peak in CdSe/ZnS-OLA sample indicates that the sample has more hydrophobic property than the two other samples.…”
Section: Resultsmentioning
confidence: 99%
“…As it can be seen in this Figure, the FTIR spectra of CdSe/ZnS-OLA showed a sharp peak at 3744 cm -1 , which is related to the stretching vibration of N-H bonds, indicating that the NH 2 -containing ligand was adsorbed on the synthesized QD surface [ 63 ] . The broad absorption peak at about 3200-3600 cm -1 can be assigned to the –OH stretching vibration of physically adsorbed water molecules in CdSe/ZnS and CdSe/ZnS-MPA samples [ 64 ] . The significant reduction of the peak in CdSe/ZnS-OLA sample indicates that the sample has more hydrophobic property than the two other samples.…”
Section: Resultsmentioning
confidence: 99%
“…[ 29 ] The characteristic bands of PNIPAAm at 1387, 1653, and 3300 cm −1 are corresponding to CH 2 , NH 2 , and NHOH groups, respectively. [ 30 ] Peaks at 3448 cm −1 indicate FeOH bond [ 31 ] and at 585 cm −1 the absorption bands of FeO in magnetite is detected, [ 32 ] which intensifies at higher concentration of MNP in fiber.…”
Section: Resultsmentioning
confidence: 99%
“…It is well-known that a passive film formed from a mixture of iron and chromium oxides/hydroxide on the electrolyte/electrode interface leads to decrease in the electrode corrosion rate in corrosive media [5]. However, some techniques such as using from corrosion inhibitors [6][7][8][9][10], alloying elements [11][12][13], and organic [14][15][16] or inorganic [17][18][19][20] coatings have been proposed by many researchers to enhance the corrosion resistance in corrosive solutions.…”
Section: Introductionmentioning
confidence: 99%