The Effect of Sensor Malpositioning on Pulse Oximeter Accuracy during Hypoxemia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0
1

Year Published

1996
1996
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(18 citation statements)
references
References 0 publications
1
16
0
1
Order By: Relevance
“…We believe that, as has been described, poor alignment of the light emitting diode and detector was responsible. 20 The SpO 2 in our infants closely resemble those found by others in nonresuscitated term infants 21,22 and mildly compromised infants resuscitated with either air or 100% oxygen. 23,24 Our findings suggest that gestation and the presence of labor have an effect on SpO 2 in the minutes after birth.…”
Section: Discussionsupporting
confidence: 87%
“…We believe that, as has been described, poor alignment of the light emitting diode and detector was responsible. 20 The SpO 2 in our infants closely resemble those found by others in nonresuscitated term infants 21,22 and mildly compromised infants resuscitated with either air or 100% oxygen. 23,24 Our findings suggest that gestation and the presence of labor have an effect on SpO 2 in the minutes after birth.…”
Section: Discussionsupporting
confidence: 87%
“…The oximeter probe must be properly positioned; clip-on devices are easy to displace, which may produce artifactual data (under-or overestimation of oxygen saturation). 361 Maximum recommended doses and durations of action are shown. Note that lower doses should be used in very vascular areas.…”
Section: Local Anesthetic Agentsmentioning
confidence: 99%
“…It is essential that any oximeter probe is properly positioned; clip-on devices are prone to easy displacement, which may produce artifactual data (underestimation or overestimation of oxygen saturation). 141,142 Capnography Expired carbon dioxide monitoring is valuable to diagnose the simple presence or absence of respirations, airway obstruction, or respiratory depression, particularly in patients sedated in less-accessible locations, such as MRI or computerized axial tomography devices or darkened rooms. 47,49,50,143,[164][165][166][167][168][169][170][171][172][173] The use of expired carbon dioxide monitoring devices is encouraged for sedated children, particularly in situations where other means of assessing the adequacy of ventilation are limited.…”
Section: Pulse Oximetrymentioning
confidence: 99%