2021
DOI: 10.1016/j.dental.2021.03.012
|View full text |Cite
|
Sign up to set email alerts
|

The effect of preparation taper on the resistance to fracture of monolithic zirconia crowns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
2

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(14 citation statements)
references
References 48 publications
1
11
2
Order By: Relevance
“…The findings of this study are consistent with Rezende et al [ 5 ], who reported that thicker cement space associated with misfit increased stress concentrations for zirconia crowns. On the other hand, the results of this study disagree with Schriwer et al [ 23 ], who reported no significant effect for cement space on fracture strength of zirconia crowns. Unfortunately, the authors are unaware of available studies on the effect of cement spacer on zirconia FPDs to compare with the obtained results in the current research.…”
Section: Discussioncontrasting
confidence: 99%
See 2 more Smart Citations
“…The findings of this study are consistent with Rezende et al [ 5 ], who reported that thicker cement space associated with misfit increased stress concentrations for zirconia crowns. On the other hand, the results of this study disagree with Schriwer et al [ 23 ], who reported no significant effect for cement space on fracture strength of zirconia crowns. Unfortunately, the authors are unaware of available studies on the effect of cement spacer on zirconia FPDs to compare with the obtained results in the current research.…”
Section: Discussioncontrasting
confidence: 99%
“…The results for marginal and internal fit in the current research agree with Grajower and Lewinstein [ 37 ], who recommended the 50 μm spacer for better fit accuracy of fixed restorations. In addition, the results of the current research are consistent withKale et al [ 22 ], and Schriwer et al [ 23 ], who reported that the 30 μm spacer jeopardized the fit accuracy of CAD-CAM zirconia.On the other hand, the results of this study disagree with Suzuki et al [ 27 ] who reported better adaptation with 30 μm spacer compared to 45 μm. However, the spacer settings assessed in this study were different.…”
Section: Discussionsupporting
confidence: 91%
See 1 more Smart Citation
“…On the contrary, there are several studies (29) (30) against the result of this study and the disagreement may be due to the concept of preserving more amount of sound tooth structure increasing the fracture resistance.…”
Section: As In Palacios R P Et Al (2006)contrasting
confidence: 64%
“…The Poisson ratio of epoxy (0.31 μ) is similar to that of dentin (0.3 μ) [ 21 ]; therefore, the degree of bulging of the epoxy model was expected to be similar to dentin during mastication when subjected to the same occlusal load. The bulging causes the development of hoop stress that causes the fracture [ 41 ]. They also showed twist hackles which are formed due to a new stress direction, having the appearance of lances where the small hackle lines merge, as well as arrest lines.…”
Section: Discussionmentioning
confidence: 99%