The Effect of Plasma Reactions on Arsenic Measurement by ICP Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 50 publications
0
6
0
Order By: Relevance
“…For example, chlorinated solvents may result in ICP-MS polyatomic interferences especially for 75 As [90] e.g. Typically helium, ammonia, hydrogen and oxygen gas are used to eliminate interferences [30,90,215] and more recently SF 6 [216]. Substitution of problem buffers, for example buffers containing chloride with carbonate, is often possible.…”
Section: Use Of Hydride Generationmentioning
confidence: 99%
See 2 more Smart Citations
“…For example, chlorinated solvents may result in ICP-MS polyatomic interferences especially for 75 As [90] e.g. Typically helium, ammonia, hydrogen and oxygen gas are used to eliminate interferences [30,90,215] and more recently SF 6 [216]. Substitution of problem buffers, for example buffers containing chloride with carbonate, is often possible.…”
Section: Use Of Hydride Generationmentioning
confidence: 99%
“…If a mobile phase containing high concentrations of sodium hydroxide is required for chromatography, the sodium will need to be removed as sodium entering the ICPMS suppresses the As signal [56,215] and causes severe baseline drift. A self-regenerating suppressor can be used to remove sodium and OH converted electrochemically to water prior to sample introduction into the ICPMS [220].…”
Section: Icpms Interferences and Signalsmentioning
confidence: 99%
See 1 more Smart Citation
“…It is well known that there are some polyatomic molecules interfering with As and Cd measurements in ICP-MS. [12][13][14] If a certain amount of Mo is contained in the samples, MoO will interfere with Cd, and especially the interference of 98 Mo 16 O with 114 Cd is very severe. 15,16 Therefore, the Cd concentrations were determined using two ICP-MSs installed with different types of the collision reaction cell gas system.…”
Section: Arsenic and Cadmium Concentrations Of Tobacco Leaves Ash Anmentioning
confidence: 99%
“…The exogenous toxic metal arsenic also suffers from a polyatomic interference in high salt solutions due to the formation of the ArCl species in the plasma, necessitating its analysis in KED mode. [19] It is possible that the use of higher resolution analysis modes, such as by sector-field ICP-MS (SF-ICP-MS) could provide higher sensitivity and lower limits of detection for challenging elements. [20]…”
Section: Discussionmentioning
confidence: 99%