2001
DOI: 10.2106/00004623-200105000-00012
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of Placing a Tensioned Graft Across Open Growth Plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
75
0
2

Year Published

2003
2003
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 165 publications
(78 citation statements)
references
References 22 publications
1
75
0
2
Order By: Relevance
“…Their conclusion was that the graft prevents bone formation across the physis. Edwards et al (2001) [9] were using a canine model as well. Their main alteration was a tensioned graft across the epiphyseal plates of 12 dogs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Their conclusion was that the graft prevents bone formation across the physis. Edwards et al (2001) [9] were using a canine model as well. Their main alteration was a tensioned graft across the epiphyseal plates of 12 dogs.…”
Section: Discussionmentioning
confidence: 99%
“…Animal studies [9,17,33] are essential steps in understanding the growing skeleton but should not be overinterpreted.…”
Section: Discussionmentioning
confidence: 99%
“…fixation or bony graft material across the physis or involve damage to the perichondral ring [24][25][26]. Based on animal models [12,36,39] and these clinical examples, the following general principles now are accepted [23,24]: fixation should not cross the physis, drill holes across the physis should be centrally located and as small as possible, and tensioning a soft tissue graft across a physis should be avoided if a large amount of growth remains.…”
Section: Introductionmentioning
confidence: 99%
“…It has been shown in animal models that: 1) ACL tunnels filled with soft tissue grafts are less likely to form physeal bars and cause shortening or angular deformity compared with empty tunnels [34,35], irrespective of the tunnel size [35]; 2) overtensioning of transphyseal grafts in skeletally immature individuals may predispose to growth disturbance [36]; 3) the amount of physeal damage and the presence of bioabsorbable devices at the level of the physis affect the chance of growth arrest [37][38][39]. Animal studies suggest that damage to less than 5% of the physis is unlikely to affect growth but that injury to 7-9% of the physis may cause a growth arrest [37][38][39].…”
Section: Growth Effects Of Physeal Damagementioning
confidence: 99%