2014
DOI: 10.1016/j.jcjd.2014.03.001
|View full text |Cite
|
Sign up to set email alerts
|

The Effect of High-Fat Diet and Streptozotocin-Induced Diabetes and Endurance Training on Plasma Levels of Calcitonin Gene-Related Peptide and Lactate in Rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 49 publications
0
3
0
Order By: Relevance
“…As a result, the lactate concentration in plasma is increased to the level typical of the lactate threshold induced by excessive physical activities. In this state, pyruvate oxidation in the mitochondria is significantly decreased, followed by the formation of lactate and elevated lactate plasma concentrations [ 37 , 43 45 ]. In morbidly obese Zucker rats, the lactate plasma concentration is increased almost 3-fold, while methyl-GBB treatment significantly improves pyruvate metabolism in mitochondria and decreases the lactate concentration almost to the control level.…”
Section: Discussionmentioning
confidence: 99%
“…As a result, the lactate concentration in plasma is increased to the level typical of the lactate threshold induced by excessive physical activities. In this state, pyruvate oxidation in the mitochondria is significantly decreased, followed by the formation of lactate and elevated lactate plasma concentrations [ 37 , 43 45 ]. In morbidly obese Zucker rats, the lactate plasma concentration is increased almost 3-fold, while methyl-GBB treatment significantly improves pyruvate metabolism in mitochondria and decreases the lactate concentration almost to the control level.…”
Section: Discussionmentioning
confidence: 99%
“…Plasma glucose was measured by glucose oxidase method (GOD-PAP) using a detection kit (Pars Azmun, Iran, 132504H917) and an autoanalyzer (Hitachi 902, Boehringer Manneheim, Germany) (28). Sensitivity and intra-and inter-assay coefficient of variations were 2 mg/ dL, 1.8% and 1.2%, respectively.…”
Section: Measurement Of Plasma Parametersmentioning
confidence: 99%
“…Triglyceride (TG) level was determined using an enzymatic-colorimetric method by commercial kit (Pars Azmun, Iran, 117504H917) and an autoanalyzer (Hitachi 902, Boehringer Manneheim, Germany) (28). Sensitivity and intra-and inter-assay coefficient of variations were 2 mg/dL, 1.7% and 1.5%, respectively.…”
Section: Measurement Of Plasma Parametersmentioning
confidence: 99%