2016
DOI: 10.1109/tdei.2016.7556475
|View full text |Cite
|
Sign up to set email alerts
|

The effect of DBDS, DBPC, BTA and DBP combinations on the corrosion of copper immersed in mineral transformer oil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…The problem of sulphur corrosion has seriously affected the safe and stable operation of transformers. In the laboratory findings, the macro-experimental research and microsimulation analysis are used to conduct in-depth analysis and F I G U R E 1 7 Protective effect of different passivators on copper sheets [68] research on the above problems, revealing the reaction mechanism as well as the influencing factors of sulphur corrosion. The macro-experimental detection can be used to study on the characteristic parameters and changes of sulphur corrosion from a large scale space.…”
Section: Field Operation Measures For Sulphur Corrosionmentioning
confidence: 99%
“…The problem of sulphur corrosion has seriously affected the safe and stable operation of transformers. In the laboratory findings, the macro-experimental research and microsimulation analysis are used to conduct in-depth analysis and F I G U R E 1 7 Protective effect of different passivators on copper sheets [68] research on the above problems, revealing the reaction mechanism as well as the influencing factors of sulphur corrosion. The macro-experimental detection can be used to study on the characteristic parameters and changes of sulphur corrosion from a large scale space.…”
Section: Field Operation Measures For Sulphur Corrosionmentioning
confidence: 99%
“…The study on their physical and chemical properties will contribute to the development of advanced corrosive resistant materials and the realization of corrosive state monitoring. Numerous efforts have been made to study properties of the DBDS, DBS, and BiBz, including chemical reactivity [7,8], synergistic effect [9,10], detection methods [6,11], etc. [12,13].…”
Section: Introductionmentioning
confidence: 99%
“…By forming an impermeable complex layer on the surface of copper, the passivator can delay the reaction between copper and DBDS [12], [13]. However, the complex layer tends to be destroyed at high temperature or under mechanical stress, and the passivator will be consumed as the power equipment runs; thus, it eventually fails to protect the windings [12], [14]. Moreover, the metal-passivation-induced stray gassing effect may affect the dissolved gas analysis of the insulating oil [15].…”
Section: Introductionmentioning