2017
DOI: 10.1016/j.cemconcomp.2016.11.012
|View full text |Cite
|
Sign up to set email alerts
|

The effect of controlled permeable formwork (CPF) liner on the surface quality of concretes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(2 citation statements)
references
References 17 publications
0
2
0
Order By: Relevance
“…e surface of concrete cast with CPF liner had a smooth and darker surface without any visible defects. Figueiras et al [7], Law et al [8,14], Kothandaraman and Kandasamy [10,11], and Liu et al [15] found that surface hardness, water absorption by capillarity, wear resistance, and abrasion resistance of concrete casted with CPF liner was significantly higher than the same concrete cast traditionally. Adam et al [13] and Law et al [14] revealed that CPF liner increased the surface properties of concrete significantly, while the improvement on bulk properties of the concrete, including resistivity, ultrasonic pulse velocity (UPV), and surface hardness, was limited.…”
Section: Introductionmentioning
confidence: 99%
“…e surface of concrete cast with CPF liner had a smooth and darker surface without any visible defects. Figueiras et al [7], Law et al [8,14], Kothandaraman and Kandasamy [10,11], and Liu et al [15] found that surface hardness, water absorption by capillarity, wear resistance, and abrasion resistance of concrete casted with CPF liner was significantly higher than the same concrete cast traditionally. Adam et al [13] and Law et al [14] revealed that CPF liner increased the surface properties of concrete significantly, while the improvement on bulk properties of the concrete, including resistivity, ultrasonic pulse velocity (UPV), and surface hardness, was limited.…”
Section: Introductionmentioning
confidence: 99%
“…The SRA mainly reduces the shrinkage of concrete by decreasing the surface tension of the pore solution [ 34 , 35 ], although some studies [ 36 ] have reported that the SRA could also reduce the evaporation rate of water in the concrete. The application of CPFL can drain out air bubbles and water while retaining fine particles like cement, which would lead to a reduced water to binder ratio and the improved structure of the concrete surface [ 22 , 37 , 38 ]. Furthermore, water absorbed by the CPFL would be also released to compensate the RH drop of concrete cover [ 23 ].…”
Section: Resultsmentioning
confidence: 99%