The Determination of Corticoids and Related Steroid Analogs by High-Performance Liquid Chromatography

Abstract: High-performance reverse-phase liquid chromatographic data on 28 corticoids and related steroid analogs, plus methyl and propyl parabens, are presented. Retention values, relative to acetone, are reported for each steroid on Bondapak Phenyl/Corasil, Bondapak C18/Corasil, and micro(micron) Bondapak C18 columns, and methanol/water or acetonitrile/water mobile phases. Ultraviolet detector response data for four of the steroids and calculated efficiencies for the three different reverse-phase columns are given. Ch… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1978
1978
2008
2008

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Therefore, the RIA method was compared with a HPLC method which separated the 11-dehydro metabolite from dexamethasone. The method used for separation was based on the previously reported procedure for the measurement of dexamethasone and other glucocorticoids by HPLC (2,(19)(20)(21).…”
Section: Reproducibility and Accuracymentioning
confidence: 99%
“…Therefore, the RIA method was compared with a HPLC method which separated the 11-dehydro metabolite from dexamethasone. The method used for separation was based on the previously reported procedure for the measurement of dexamethasone and other glucocorticoids by HPLC (2,(19)(20)(21).…”
Section: Reproducibility and Accuracymentioning
confidence: 99%
“…A number of methods involving normal- [11,12] or reverse-phase HPLC [13][14][15][16][17] have been introduced for the determination of serum adrenal steroids. In the case of normal-phase HPLC, the elution of highly polar ste roids such as E and F takes a long time, and therefore a gradient system needs to be employed as the mobile Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Thin-layer chromatography (TLC) Talukar and Datta 1969;Gossele 1971;Lemieszek-Chodorowska and Snycerski 1971;Sarsunova 1973;Thielemann 1975;Valdehita et al 1979 TLC/ultraviolet spectroscopy Tiscornia andStacchini 1964;Ludwig andFreimuth 1965, Nagasawa et al 1969;Tammilehto and Buchi 1969;Ficicchia and DelMastro 1977 High-performance liquid chromatography Kitada et al 1980;Terada and Sakabe 1985;Shiromea and Oshiro 1986;Maeda et al 1987;Talukar and Datta 1969;Lemieszek-Chodorowska and Snycerski 1971;Fujiwara et al 1971;Gossele 1971;Sarsunova 1973;Fitzpatrick et al 1975;Laurent and Bourdon 1975;Thielemann 1975;Wilson 1975;Caude and Le 1976;Clarke and Rashid 1977;Cox et al 1977;Tymes 1977;Yost et al 1977;Austin and Mather 1978;Brown et al 1978a;Sauermann et al 1978, Lee 1979Leuenberger et al 1979;Valdehita et al 1979 Gas chromatography (GC) Iguchi et al 1963;Nishimoto and Uyeta 1965;Vogel and Deshusses 1965;Gupta and Lundberg 1977;Jensen 19...…”
Section: Methods Referencesmentioning
confidence: 99%