The dependence of patient dose on factors relating to the technique and complexity of Interventional Cardiology procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
6
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 16 publications
1
6
0
Order By: Relevance
“…The average DAP of 158.2 Gycm 2 found in this study is within the range reported in the literature (28.5-370.6 Gycm 2 ) [24,[36][37][38][39][40][41], but higher than the reference dose level of 75 Gycm 2 established by the European Cardiology research programme DIMOND [37]. A 300 Gycm 2 threshold has also been set for probable induction of skin injury by the European DIMOND research programme.…”
Section: Discussionsupporting
confidence: 82%
See 1 more Smart Citation
“…The average DAP of 158.2 Gycm 2 found in this study is within the range reported in the literature (28.5-370.6 Gycm 2 ) [24,[36][37][38][39][40][41], but higher than the reference dose level of 75 Gycm 2 established by the European Cardiology research programme DIMOND [37]. A 300 Gycm 2 threshold has also been set for probable induction of skin injury by the European DIMOND research programme.…”
Section: Discussionsupporting
confidence: 82%
“…Numerous studies have found that the radiation dose varies significantly according to tube angulations, particularly in the combination of steep left anterior oblique (LAO) with cranial or caudal angulations [24][25][26][27]. However, there are no published data on whether the radiation dose with biplane or single-plane imaging during coronary angioplasty differs between the three vascular territories: right coronary artery (RCA), left anterior descending (LAD) and left circumflex/intermediate (LCX).…”
mentioning
confidence: 99%
“…minimising the X-ray dose to the patient while preserving the quality of treatment), the use of low fluoroscopy pulse rate, image intensifier field size and collimation are recommended [1,12,13]. However, the studies that concluded that there was an impact on dose of some technical parameters had mostly used descriptive or univariate analyses and/or were carried out on a phantom [2,4,14,15]. Few studies have used multivariate methods to analyse the dose variation on patients' skin [13,16].…”
mentioning
confidence: 99%
“…First of all, the dose to the patient increases with increasing body mass index (BMI) [1][2][3]. Second, dose, fluoroscopy time and number of cine frames might differ depending on the number of treated vessels and/or stenoses [4][5][6], localisation and severity of lesions [2,7], stage of occlusion [7,8], tortuosity of treated vessels [6][7][8], number of stents and balloons [2,4,[7][8][9], and artery approach [10,11]. With the aim of optimising the interventional cardiology procedures (i.e.…”
mentioning
confidence: 99%
“…Delichas et al found that the radiation dose to the patient is influenced by the individual characteristics of each interventional procedure [76]. The maximal annual dose values received by 9 cardiologists during 144 cardiac procedures in two hospitals in their study were found to be 1.9 and 2.8 mSv, which are much higher than the reference levels defined by the European DIMOND approach [77].…”
Section: Radiation-induced Risks To Patientsmentioning
confidence: 95%