The data acquisition system of ClearPET neuro - a small animal PET scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(29 citation statements)
references
References 6 publications
0
29
0
Order By: Relevance
“…The data acquisition system of the ClearPET [16] consists of 20 detector cassettes, each comprising 4 PMTs and electronics for trigger, shaping, data-digitization (free-running analog-to-digital converters, ADC, at 40 MHz sampling rate and 12-bit resolution) and transmission. These cassettes transfer their data via fiber optics to five preprocessing PCs (four cassettes per PC) which provide list-mode files with the information of each single photon detected.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The data acquisition system of the ClearPET [16] consists of 20 detector cassettes, each comprising 4 PMTs and electronics for trigger, shaping, data-digitization (free-running analog-to-digital converters, ADC, at 40 MHz sampling rate and 12-bit resolution) and transmission. These cassettes transfer their data via fiber optics to five preprocessing PCs (four cassettes per PC) which provide list-mode files with the information of each single photon detected.…”
Section: Methodsmentioning
confidence: 99%
“…Correction for random events was only applied in the ClearPET. The rPET-1 system does not provide correction for randoms; however, at the usual activities in mouse studies (15)(16)(17)(18)(19)(20) MBq) the randoms fraction is below 5% of the total coincidences. The values presented in the image quality test were obtained without applying attenuation or scatter corrections.…”
Section: Image Qualitymentioning
confidence: 99%
“…Its detectors, frontend electronics and data acquisition architecture are based on the ClearPET TM system (Streun et al, 2006). The detectors are arranged in a horizontal plane to allow the plants to be measured in their natural upright position.…”
Section: Data Collection and Analysis During The Half-girdling Experimentioning
confidence: 99%
“…The production and the application of the short lived carbon isotope labelled 11 C-CO 2 through a gas-exchange system has been described by Jahnke et al (2009). Quantitative analysis of the distribution of 11 C-isotope in the root/soil volume was conducted by a PET setup dedicated for plant analysis (PLANTIS) based in the CLEARPET-system (Streun et al 2006) in a coincidence design. Reconstruction used the specifically designed algorithms (Weber et al 2006).…”
Section: Analysis Of Root Structure and Function In Soilmentioning
confidence: 99%
“…Findings obtained in those artificial conditions must be verified in natural substrates at full 3-D resolution. Recently, combinations of MRI and PET have been developed and applied to analyse root and storage structure (MRI) as well as carbon transport properties (PET) in soil (Streun et al 2006;Jahnke et al 2009). In the present study we report on first applications of this co-registration method of MRI and PET to analyse responses of plant roots to environmental challenges emphasising the carbon transport into the root at cool temperatures.…”
Section: Analysis Of Root Structure and Function In Soilmentioning
confidence: 99%