2016
DOI: 10.1002/nau.23063
|View full text |Cite
|
Sign up to set email alerts
|

The correlation between retrograde leak point pressure and 24‐hour pad weight

Abstract: RLPP could be used as an objective and potentially more reliable substitute to pad weight to objectify and stratify SUI in post-prostatectomy patients. Neurourol. Urodynam. 36:1119-1123, 2017. © 2016 Wiley Periodicals, Inc.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 26 publications
(46 reference statements)
0
5
0
Order By: Relevance
“…Retrograde perfusion (RLPP) Fig. 2 Frequency of preoperative urodynamic parameters grouped by surgical outcome eliminates the storage bladder function and as result is a more direct measurement of residual sphincteric function [15]. RLPP was performed at one of the three institutions (in 60/130 men).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Retrograde perfusion (RLPP) Fig. 2 Frequency of preoperative urodynamic parameters grouped by surgical outcome eliminates the storage bladder function and as result is a more direct measurement of residual sphincteric function [15]. RLPP was performed at one of the three institutions (in 60/130 men).…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, pad number (weight) may represent an indirect measurement of overall bladder function rather than sphincter function (weakness), given the impact of low bladder capacity and DO on surgical outcomes. Retrograde perfusion (RLPP) eliminates the storage bladder function and as result is a more direct measurement of residual sphincteric function [ 15 ]. RLPP was performed at one of the three institutions (in 60/130 men).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…4 Our recent data have demonstrated that RLPP is also correlated with 24-hour pad weight and may be a better objective assessment of sphincter weakness than the subjective collection of pad number or pad weight. 6 RLPP measurement was performed as described by Comiter et al 3 with some minor modifications to improve reliability and patient comfort. A 6 Fr double lumen catheter is introduced up to the distal bulbar urethra with the patient in the supine position.…”
Section: Video Urodynamics and Rlppmentioning
confidence: 99%
“…4 Our recent data have demonstrated that RLPP is also correlated with 24-hour pad weight and may be a better objective assessment of sphincter weakness than the subjective collection of pad number or pad weight. 6…”
Section: What Are the Important Aspects Of The History In Deciding Fumentioning
confidence: 99%