2013
DOI: 10.1111/clr.12256
|View full text |Cite
|
Sign up to set email alerts
|

The comparison between implant stability quotient and bone‐implant contact revisited: an experiment in Beagle dog

Abstract: The lack of correlation between BIC and ISQ values suggests that ISQ as determined by RFA is not able to identify the relationship between RF and histomorphometrical data.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
45
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(48 citation statements)
references
References 54 publications
2
45
1
Order By: Relevance
“…Although the ISQ and PTV are widely used to noninvasively monitor implant stability, their associations with histomorphometric data during the healing process are still controversial and have not been definitively established [8, 21–23]. Therefore, the present study investigated whether implant stability parameters (ISQ and PTV values) correlated with peri-implant-bone healing (osseointegration, BIC values) at various healing time points.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Although the ISQ and PTV are widely used to noninvasively monitor implant stability, their associations with histomorphometric data during the healing process are still controversial and have not been definitively established [8, 21–23]. Therefore, the present study investigated whether implant stability parameters (ISQ and PTV values) correlated with peri-implant-bone healing (osseointegration, BIC values) at various healing time points.…”
Section: Discussionmentioning
confidence: 99%
“…The femoral condyles containing the implants were harvested using a diamond circular saw and subsequently fixed in 10% formalin solution for 7 days. Whole implant-bone samples were then processed without decalcification for ground sectioning according to the previous studies [8, 23]. In brief, the specimens were dehydrated in a graded series of ethanol (70% to 100%) over a period of 24 hours at 5°C and defatted in xylene under vacuum.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Recent in vivo studies [30][31][32] investigated the correlation between resonance frequency analysis (ISQ value) and % BIC values in dental implants inserted in dog mandibles and human jaws. The authors concluded that there is a lack of correlation between these 2 values, and they could not identify the relationship between RFA and histomorphometrical data.…”
Section: Discussionmentioning
confidence: 99%