2016
DOI: 10.1111/aor.12875
|View full text |Cite
|
Sign up to set email alerts
|

The Clinical Importance of Pulsatile Flow in Extracorporeal Life Support: The Penn State Health Approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2

Relationship

5
3

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 16 publications
2
15
0
Order By: Relevance
“…Our results once again showed that the i‐cor diagonal pump can generate non‐pulsatile and ECG‐synchronized pulsatile flow in our simulated pediatric and adult ECLS circuits . The i‐cor diagonal pump can generate pulsatile flow by changing the rotational speed.…”
Section: Discussionsupporting
confidence: 64%
“…Our results once again showed that the i‐cor diagonal pump can generate non‐pulsatile and ECG‐synchronized pulsatile flow in our simulated pediatric and adult ECLS circuits . The i‐cor diagonal pump can generate pulsatile flow by changing the rotational speed.…”
Section: Discussionsupporting
confidence: 64%
“…It can also be used as a bridge to a ventricular assist device (VAD) or cardiac transplantation, and it may be conveniently placed at the catheterization laboratory, the intensive care unit, the emergency department, or the operating room. Recently, significant technological advances have led to improved VA‐ECMO survival and reduced complications . However, according to the July 2017 Extracorporeal Life Support Organization (ELSO) Registry Report, the survival‐to‐hospital discharge rate in adult patients with cardiogenic shock on ECMO is only 42% .…”
mentioning
confidence: 99%
“…The combination therapy using nonpulsatile centrifugal pump with a pulsatile IABP has conflicting reports regarding the patients' outcomes despite an additional cost of usage of IABP . The ideal ECLS system should provide synchronized pulsatile blood flow to mimic the physiological pulsatile flow patterns and match with patient's pulse .…”
mentioning
confidence: 99%
“…The use of pulsatile flow during acute or chronic mechanical circulatory support for pediatric or adult patients is one of the major research areas at the Penn State Hershey Pediatric Cardiovascular Research Center. [16][17][18][19] The predecessor of the PediMag centrifugal pump was the Levitronix PediVAS system, which is capable of generating pulsatile flow and has been tested in an experimental setting at our research center. This pulsatile module was intended for experimental use only and has not been approved by the Food and Drug Administration (FDA) for use in clinical practice.…”
Section: Discussionmentioning
confidence: 99%