Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…Accordingly, total reflection is observed for incidence angles that are larger than the angle of total reflection of the scintillator-grease interface, (4) For a plain coupling face and , is of the order of 50 and 55 for LuYAP and LYSO, respectively.…”
Section: Discussion Of Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…Accordingly, total reflection is observed for incidence angles that are larger than the angle of total reflection of the scintillator-grease interface, (4) For a plain coupling face and , is of the order of 50 and 55 for LuYAP and LYSO, respectively.…”
Section: Discussion Of Resultsmentioning
confidence: 98%
“…The present work evaluates the impact of various structural parameters of a PhC on light extraction and presents a simple approach which allows for estimating the effect of the PhC on for a given scintillator. The main focus of the study is on the two heavy inorganic scintillators LuYAP and LYSO that have been used in the dedicated PET systems 0018-9499/$26.00 © 2010 IEEE ClearPET and ClearPEM developed by the Crystal Clear Collaboration [4], [5]; however, the results presented herein are also valid for many other scintillators with comparable optical properties.…”
mentioning
confidence: 99%
“…The scintillation element with cross-section 2 Â 2 mm is individually read out with PSPMT pixel that gives spatial resolution of about 1.5 mm FWHM in CFOV (with 18 F). In addition depth of interaction (DOI) determination capability is provided by double layer LSO/LuYAP phoswich detector with pulse shape layer discrimination to improve spatial resolution on the periphery of the field of view [2,3], Fig. 1.…”
Section: Modern Trends In the Pet Detector Developmentmentioning
confidence: 99%
“…We describe the development and the performance measurements of an optimized LSO/LuYAP phoswich detector head for the ClearPET demonstrator, which is built in Lausanne among five prototypes developed within the Crystal Clear Collaboration (CCC). The five prototypes are all using the same technology, but with different crystal sizes and phoswich encapsulations [1], [2]. With small diameter tomographs, the uncertainty on the depth-of-interaction (DOI) of the impinging photon in the scintillating crystal results in parallax errors that degrade image resolution when getting away from the axis of the tomograph.…”
Section: Introductionmentioning
confidence: 99%