2008 International Conference on Technology and Applications in Biomedicine 2008
DOI: 10.1109/itab.2008.4570616
|View full text |Cite
|
Sign up to set email alerts
|

The beat-to-beat relationship between pulse transit time and systolic blood pressure

Abstract: Non-invasive measurement of beat-to-beat arterial blood pressure (BP) is an interesting but currently unsolved topic in long-term physiological monitoring by wearable devices and body sensor networks. Although it is suggested that pulse transit time (PTT) is related to and can be used to estimate BP, few studies showed how their relationship changes over time. This study reported the beat-to-beat correlation between PTT and invasive BP of short segments for 4 subjects during an 8-hour period. The results of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
15
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 16 publications
(17 citation statements)
references
References 4 publications
2
15
0
Order By: Relevance
“…11 It can be seen that the G in (7) only depends on the changes of R and P. However, the G in (5) depends on other factors beside R and P, such as age and gender. This implies that the G in (5) and (7) have different connotations and perhaps it is improper to obtain model (4) by canceling G in the intermediate steps.…”
Section: Current Status Of Bp Measurement Based On Pwvmentioning
confidence: 96%
See 3 more Smart Citations
“…11 It can be seen that the G in (7) only depends on the changes of R and P. However, the G in (5) depends on other factors beside R and P, such as age and gender. This implies that the G in (5) and (7) have different connotations and perhaps it is improper to obtain model (4) by canceling G in the intermediate steps.…”
Section: Current Status Of Bp Measurement Based On Pwvmentioning
confidence: 96%
“…The model coefficients are identified by individual calibration. 1,3,4,6,7,[9][10][11][12]15 Theoretical modeling of the relationship between BP and PTT/PWV is a crucial part in the methodology above. So far, the proposed theoretical models fall into two categories: linear models and nonlinear models.…”
Section: Current Status Of Bp Measurement Based On Pwvmentioning
confidence: 99%
See 2 more Smart Citations
“…5 After this period, which is usually of the order of minutes, the BP needs to be measured again. 6,7 The time between subsequent BP measurements is known as the calibration interval. This calibration is required because of the assumptions made in the derivation of the algorithm that calculates BP from the PTT measurement.…”
Section: Introductionmentioning
confidence: 99%