2020
DOI: 10.11591/ijece.v10i6.pp5621-5630
|View full text |Cite
|
Sign up to set email alerts
|

The assesement of the shunt active filter efficiency under varied power supply source and load parameters

Abstract: The results of theoretical and experimental studies on the problems of effective application of shunt active filters for power quality improvement and electromagnetic compatibility ensuring were presented in this article. Based on the different theories and methods, the most effective and well-studied control algorithms of shunt active filters were determined and analyzed to ensure their effective application in distributed generation systems and combined power supply systems. Mathematical and computer simulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 40 publications
0
15
0
Order By: Relevance
“…Let's consider the following positive definite Lyapunov function given as (6). The derivative of the Lyapunov function ( 6) is given as (7).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Let's consider the following positive definite Lyapunov function given as (6). The derivative of the Lyapunov function ( 6) is given as (7).…”
Section: Methodsmentioning
confidence: 99%
“…Voltage source inverters (VSIs), in particular, are commonly used for interfacing renewable energy sources and energy storage systems with the primary grid [12], [13]. VSIs have many applications including output voltage and current control [10], [13]- [17], active power filtering [3], [7], [18]- [20], and power factor compensation [21], [22], among other applications [4], [5].…”
Section: Introductionmentioning
confidence: 99%
“…The THD of 4.3% and 4.7% for balanced and unbalanced load is achieved respectively for shunt hybrid compensator with 26V DC link voltage. Sychev et al [26] present the shunt-active filter to analyze the efficiency parameter by varying the source and load parameters. The shunt active filter is modeled in five different ways.…”
Section: Review On Related Researchmentioning
confidence: 99%
“…Also, in this case it is necessary to have a multifunctional device to improve power quality under changing power supply parameters and connected load characteristics [12], [13]. There are plenty of such devices, and it is reasonable to consider in detail hybrid filters which are based on active and passive filters [14], [15]. Any hybrid structure includes a series or shunt active filter with one or several resonance passive filters or with one wide-band passive filter.…”
Section: Introductionmentioning
confidence: 99%