2003
DOI: 10.1023/a:1026160731601
|View full text |Cite
|
Sign up to set email alerts
|

The application and development of k0-standardization method of neutron activation analysis at Dalat research reactor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2008
2008
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(14 citation statements)
references
References 2 publications
0
13
0
1
Order By: Relevance
“…This figure shows that the curve profiles are nearly the same for all tube diameters. The efficiency curve has a knee at approximately 80 keV and the lower efficiency that was observed in the range below this knee arises from the absorption of the low-energy photons by the cladding material of the detector [26].…”
Section: Resultsmentioning
confidence: 99%
“…This figure shows that the curve profiles are nearly the same for all tube diameters. The efficiency curve has a knee at approximately 80 keV and the lower efficiency that was observed in the range below this knee arises from the absorption of the low-energy photons by the cladding material of the detector [26].…”
Section: Resultsmentioning
confidence: 99%
“…the calibration of full energy peak efficiency for gamma-ray spectrometer (e p ), the determination of neutron parameters for irradiation facility (a, f, f F , fluxes), the correction of interference nuclear reactions and the report of results (mass fraction of elements, uncertainty and detection limit), etc. It should be noted that the software has worked out the neutron parameters calculation based on gamma-ray spectra of the Au and Zr monitors ( 198 Au and 95 Zr/ 97 Zr, respectively) for a and f factors while the Co, Ni and Au monitors ( 58 Co, 65 Ni and 198 Au, respectively) were used for the calculation of thermal to fast neutron fluxes ratio (f F ) and the neutron fluxes as well [1,18]. The correction of interference nuclear reactions, Results and discussion Table 1 shows the mass fractions of elements and uncertainties in mg/kg for three types of SMELS (I, II & III) along with the x lab /x ref ratios, relative biases (RBs) and uscores Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The k 0 -standardized neutron activation analysis (k 0 -NAA) has been studied and applied at the 500 kW Dalat research reactor (DRR) of Vietnam for over 15 years [1][2][3]. Successful introduction of k 0 -NAA using ''Ko-Dalat'' software has allowed to extend its applications to the samples of petroleum, archaeology and environment besides other traditional fields, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…The K0-Dalat program [29,30] is applied to calculate the elemental concentrations, the uncertainties, and the detection limits. Figure 2 are the XRD patterns of the -MnO 2 nanostructure.…”
Section: Gamma Activity Measurementmentioning
confidence: 99%