The affinity of bone to hydroxyapatite and alumina in experimentally induced osteoporosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

1992
1992
2004
2004

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 45 publications
(14 citation statements)
references
References 16 publications
0
14
0
Order By: Relevance
“…[27][28][29] Søballe et al 30 studied the ingrowth of osteopenic bone into titanium-alloy porous-coated implants with and without HA coating in dogs and concluded that HA-coated implants were not affected by the osteopenic condition. This is the only report in which the integrity between an HA-coated implant and osteoporotic bone has been evaluated mechanically.…”
Section: Discussionmentioning
confidence: 99%
“…[27][28][29] Søballe et al 30 studied the ingrowth of osteopenic bone into titanium-alloy porous-coated implants with and without HA coating in dogs and concluded that HA-coated implants were not affected by the osteopenic condition. This is the only report in which the integrity between an HA-coated implant and osteoporotic bone has been evaluated mechanically.…”
Section: Discussionmentioning
confidence: 99%
“…The affinity index of each section was calculated by dividing this length by the total length of the bone-cement interface and multiplying by 100. 28,33 Mechanical testing A method of the push-out test was described in detail in our previous report. 28 Briefly, the cement and femoral component were pushed together with a metal rod 6 mm in diameter at a crosshead speed of 0.5 mm per min, using an Instron-type testing machine (Autograph Model AG-10TG, Shimazu, Kyoto, Japan).…”
Section: Affinity Indexmentioning
confidence: 99%
“…1,[7][8][9][10][11] Some reports suggest that implants are prone to failure as a result of the diminished capacity for bone remodeling, and hence osseointegration and biomechanical maintenance of the implant, within osteoporotic bone, 12,13 whereas other reports have promoted the use of dental implants in the edentulous mandible to minimize physiological and age-related bone loss. 9,14,15 Several studies using either administration of glucocorticoids or ovariectomized animal models have been conducted to address the concerns of implant use under experimentally induced osteoporotic-like conditions. 12,16 -19 The aim of this study was to determine the level of implant osseointegration in osteoporotic-like bone using an ovariectomized rat animal model.…”
mentioning
confidence: 99%