2006
DOI: 10.1111/j.1525-1594.2007.00337.x
|View full text |Cite
|
Sign up to set email alerts
|

The Acute Effect of Intra‐aortic Balloon Counterpulsation During Extracorporeal Life Support: An Experimental Study

Abstract: Hemodynamically unstable patients supported by an extracorporeal life support (ECLS) circuit often receive additional support by intra-aortic balloon pump (IABP). However, it is not established whether support of the failing heart is improved by adjunctive IABP in both peripheral cannulation (PC) and central cannulation (CC) settings. Seven sheep were supported by an IABP and an ECLS system which were cannulated centrally as well as peripherally. In each cannulation configuration, hemodynamic and cardiac funct… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
34
0
1

Year Published

2008
2008
2020
2020

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 60 publications
(41 citation statements)
references
References 26 publications
4
34
0
1
Order By: Relevance
“…We speculate that an intermittent aortic occlusion by the IABP balloon may diminish blood flow available for the aortic root (and thus for coronary arteries), more than for the aortic arch (and thus for the carotids). These results are in accordance with a report by Sauren [34], where addition of IABP in severely hypotensive ECMO-treated animals was not beneficial; however, the animals were not in cardiac arrest. On the other hand, the subclavian approach seems to be suitable for IABP assistance because the outflow cannula is located proximal to the IABP balloon.…”
Section: Discussionsupporting
confidence: 93%
“…We speculate that an intermittent aortic occlusion by the IABP balloon may diminish blood flow available for the aortic root (and thus for coronary arteries), more than for the aortic arch (and thus for the carotids). These results are in accordance with a report by Sauren [34], where addition of IABP in severely hypotensive ECMO-treated animals was not beneficial; however, the animals were not in cardiac arrest. On the other hand, the subclavian approach seems to be suitable for IABP assistance because the outflow cannula is located proximal to the IABP balloon.…”
Section: Discussionsupporting
confidence: 93%
“…Multidisciplinary monitoring and management may well be the key to success . A principal goal during ECMO should be to ensure that the aortic valve opens and that some blood flows through the chambers, particularly when the left ventricular function is severely compromised; this may be achieved by IV infusion of a moderate dose of inotropes and use of IABP . Additionally, strict peripheral vascular perfusion Doppler monitoring should be performed to avoid deleterious leg complications .…”
Section: Discussionmentioning
confidence: 99%
“…An experimental study suggested that IABP-induced pulsatility improves coronary bypass graft flows during nonpulsatile ECLS [11]. Another study proposed that adjunctive IABP improves the myocardial oxygen supply–demand balance in peripheral extracorporeal life support [12]. These benefits of IABP might increase coronary flow during diastole and compensate for limitations of ECLS, such as myocardial oxygen consumption associated with increased LV afterload.…”
Section: Discussionmentioning
confidence: 99%