BackgroundThe aim of this study was to assess the relationship between extracorporeal blood flow (EBF) and left ventricular (LV) performance during venoarterial extracorporeal membrane oxygenation (VA ECMO) therapy.MethodsFive swine (body weight 45 kg) underwent VA ECMO implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock with signs of tissue hypoxia was induced. Hemodynamic and cardiac performance parameters were then measured at different levels of EBF (ranging from 1 to 5 L/min) using arterial and venous catheters, a pulmonary artery catheter and a pressure–volume loop catheter introduced into the left ventricle.ResultsMyocardial hypoxia resulted in a decline in mean (±SEM) cardiac output to 2.8 ± 0.3 L/min and systolic blood pressure (SBP) to 60 ± 7 mmHg. With an increase in EBF from 1 to 5 L/min, SBP increased to 97 ± 8 mmHg (P < 0.001); however, increasing EBF from 1 to 5 L/min significantly negatively influences several cardiac performance parameters: cardiac output decreased form 2.8 ± 0.3 L/min to 1.86 ± 0.53 L/min (P < 0.001), LV end-systolic volume increased from 64 ± 11 mL to 83 ± 14 mL (P < 0.001), LV stroke volume decreased from 48 ± 9 mL to 40 ± 8 mL (P = 0.045), LV ejection fraction decreased from 43 ± 3 % to 32 ± 3 % (P < 0.001) and stroke work increased from 2096 ± 342 mmHg mL to 3031 ± 404 mmHg mL (P < 0.001). LV end-diastolic pressure and volume were not significantly affected.ConclusionsThe results of the present study indicate that higher levels of VA ECMO blood flow in cardiogenic shock may negatively affect LV function. Therefore, it appears that to mitigate negative effects on LV function, optimal VA ECMO blood flow should be set as low as possible to allow adequate tissue perfusion.
IntroductionExtracorporeal membrane oxygenation (ECMO) is increasingly used in cardiac arrest (CA). Adequacy of carotid and coronary blood flows (CaBF, CoBF) and coronary perfusion pressure (CoPP) in ECMO treated CA is not well established. This study compares femoro-femoral (FF) to femoro-subclavian (FS) ECMO and intraaortic balloon counterpulsation (IABP) contribution based on CaBF, CoBF, CoPP, myocardial and brain oxygenation in experimental CA managed by ECMO.MethodsIn 11 female pigs (50.3 ± 3.4 kg), CA was randomly treated by FF versus FS ECMO ± IABP. Animals under general anesthesia had undergone 15 minutes of ventricular fibrillation (VF) with ECMO flow of 5 to 10 mL/kg/min simulating low-flow CA followed by continued VF with ECMO flow of 100 mL/kg/min. CaBF and CoBF were measured by a Doppler flow wire, cerebral and peripheral oxygenation by near infrared spectroscopy. CoPP, myocardial oxygen metabolism and resuscitability were determined.ResultsCaBF reached values > 80% of baseline in all regimens. CoBF > 80% was reached only by the FF ECMO, 90.0% (66.1, 98.6). Addition of IABP to FF ECMO decreased CoBF to 60.7% (55.1, 86.2) of baseline, P = 0.004. FS ECMO produced 70.0% (49.1, 113.2) of baseline CoBF, significantly lower than FF, P = 0.039. Addition of IABP to FS did not change the CoBF; however, it provided significantly higher flow, 76.7% (71.9, 111.2) of baseline, compared to FF + IABP, P = 0.026. Both brain and peripheral regional oxygen saturations decreased after induction of CA to 23% (15.0, 32.3) and 34% (23.5, 34.0), respectively, and normalized after ECMO institution. For brain saturations, all regimens reached values exceeding 80% of baseline, none of the comparisons between respective treatment approaches differed significantly. After a decline to 15 mmHg (9.5, 20.8) during CA, CoPP gradually rose with time to 68 mmHg (43.3, 84.0), P = 0 .003, with best recovery on FF ECMO. Resuscitability of the animals was high, both 5 and 60 minutes return of spontaneous circulation occured in eight animals (73%).ConclusionsIn a pig model of CA, both FF and FS ECMO assure adequate brain perfusion and oxygenation. FF ECMO offers better CoBF than FS ECMO. Addition of IABP to FF ECMO worsens CoBF. FF ECMO, more than FS ECMO, increases CoPP over time.
IntroductionVeno-arterial extracorporeal life support (ECLS) is increasingly being used to treat rapidly progressing or severe cardiogenic shock. However, it has been repeatedly shown that increased afterload associated with ECLS significantly diminishes left ventricular (LV) performance. The objective of the present study was to compare LV function and coronary flow during standard continuous-flow ECLS support and electrocardiogram (ECG)-synchronized pulsatile ECLS flow in a porcine model of cardiogenic shock.MethodsSixteen female swine (mean body weight 45 kg) underwent ECLS implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock, with documented signs of tissue hypoperfusion, was induced by initiating global myocardial hypoxia. Hemodynamic cardiac performance variables and coronary flow were then measured at different rates of continuous or pulsatile ECLS flow (ranging from 1 L/min to 4 L/min) using arterial and venous catheters, a pulmonary artery catheter, an LV pressure-volume loop catheter, and a Doppler coronary guide-wire.ResultsMyocardial hypoxia resulted in declines in mean cardiac output to 1.7±0.7 L/min, systolic blood pressure to 64±22 mmHg, and LV ejection fraction (LVEF) to 22±7%. Synchronized pulsatile flow was associated with a significant reduction in LV end-systolic volume by 6.2 mL (6.7%), an increase in LV stroke volume by 5.0 mL (17.4%), higher LVEF by 4.5% (18.8% relative), cardiac output by 0.37 L/min (17.1%), and mean arterial pressure by 3.0 mmHg (5.5%) when compared with continuous ECLS flow at all ECLS flow rates (P<0.05). At selected ECLS flow rates, pulsatile flow also reduced LV end-diastolic pressure, end-diastolic volume, and systolic pressure. ECG-synchronized pulsatile flow was also associated with significantly increased (7% to 22%) coronary flow at all ECLS flow rates.ConclusionECG-synchronized pulsatile ECLS flow preserved LV function and coronary flow compared with standard continuous-flow ECLS in a porcine model of cardiogenic shock.
Despite the urgent need for experimental research in the field of acute heart failure and, particularly cardiogenic shock, currently there are only limited options in large animal models enabling research using devices applied to human subjects. The majority of available models are either associated with an unacceptably high rate of acute mortality or are incapable of developing sufficient severity of acute heart failure. The objective of our research was to develop a novel large animal model of acute severe cardiogenic shock. Advanced left ventricular dysfunction was induced by global myocardial hypoxia by perfusing the upper body (including coronary arteries) with deoxygenated venous blood. The model was tested in 12 pigs: cardiogenic shock with signs of tissue hypoxia developed in all animals with no acute mortality. Cardiac output decreased from a mean (± SD) of 6.61±1.14 l/min to 2.75±0.63 l/min, stroke volume from 79.7±9.8 ml to 25.3±7.8 ml and left ventricular ejection fraction from 61.2±4.3 % to 17.7±4.8 % (P≤0.001 for all comparisons). In conclusion, the porcine model of acute cardiogenic shock developed in the present study may provide a basis for studying severe left ventricular dysfunction, low cardiac output and hypotension in large animals. The global myocardial hypoxia responsible for the decrease in cardiac contractility was not associated with acute death in this model.
Background-Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. Methods and Results-Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. Conclusions-Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation. (Circ Arrhythm Electrophysiol. 2012;5:1202-1206.)
BackgroundMild therapeutic hypothermia (HT) has been implemented in the management of post cardiac arrest (CA) syndrome after the publication of clinical trials comparing HT with common practice (ie, usually hyperthermia). Current evidence on the comparison between therapeutic HT and controlled normothermia (NT) in CA survivors, however, remains insufficient.MethodsEight female swine (sus scrofa domestica; body weight 45 kg) were randomly assigned to receive either mild therapeutic HT or controlled NT, with four animals per group. Veno-arterial extracorporeal membrane oxygenation (ECMO) was established and at minimal ECMO flow (0.5 L/min) ventricular fibrillation was induced by rapid ventricular pacing. After 20 min of CA, circulation was restored by increasing the ECMO flow to 4.5 L/min; 90 min of reperfusion followed. Target core temperatures (HT: 33°C; NT: 36.8°C) were maintained using the heat exchanger on the oxygenator. Invasive blood pressure was measured in the aortic arch, and cerebral oxygenation was assessed using near-infrared spectroscopy. After 60 min of reperfusion, up to three defibrillation attempts were performed. After 90 min of reperfusion, blood samples were drawn for the measurement of troponin I (TnI), myoglobin (MGB), creatine-phosphokinase (CPK), alanin-aminotransferase (ALT), neuron-specific enolase (NSE) and cystatin C (CysC) levels. Reactive oxygen metabolite (ROM) levels and biological antioxidant potential (BAP) were also measured.ResultsSignificantly higher blood pressure and cerebral oxygenation values were observed in the HT group (P<0.05). Sinus rhythm was restored in all of the HT animals and in one from the NT group. The levels of TnI, MGB, CPK, ALT, and ROM were significantly lower in the HT group (P<0.05); levels of NSE, CysC, and BAP were comparable in both groups.ConclusionsOur results from animal model of cardiac arrest indicate that HT may be superior to NT for the maintenance of blood pressure, cerebral oxygenation, organ protection and oxidative stress suppression following CA.
Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in treatment of decompensated heart failure. Our aim was to investigate its effects on regional perfusion and tissue oxygenation with respect to extracorporeal blood flow (EBF). In five swine, decompensated low-output chronic heart failure was induced by long-term rapid ventricular pacing. Subsequently, VA ECMO was introduced and left ventricular (LV) volume, aortic blood pressure, regional arterial flow and tissue oxygenation were continuously recorded at different levels of EBF. With increasing EBF from minimal to 5 l/min, mean arterial pressure increased from 47±22 to 84±12 mm Hg (P<0.001) and arterial blood flow increased in carotid artery from 211±72 to 479±58 ml/min (P<0.01) and in subclavian artery from 103±49 to 296±54 ml/min (P<0.001). Corresponding brain and brachial tissue oxygenation increased promptly from 57±6 to 74±3 % and from 37±6 to 77±6 %, respectively (both P<0.01). Presented results confirm that VA ECMO is a capable form of heart support. Regional arterial flow and tissue oxygenation suggest that partial circulatory support may be sufficient to supply brain and peripheral tissue by oxygen.
The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25°, 45°, and 60° respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45° and 60° models. In the 25° model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.