2012
DOI: 10.1063/1.4731001
|View full text |Cite
|
Sign up to set email alerts
|

Testing a new NIF neutron time-of-flight detector with a bibenzyl scintillator on OMEGA

Abstract: A new neutron time-of-flight (nTOF) detector with a bibenzyl crystal as a scintillator has been designed and manufactured for the National Ignition Facility (NIF). This detector will replace a nTOF20-Spec detector with an oxygenated xylene scintillator currently operational on the NIF to improve the areal-density measurements. In addition to areal density, the bibenzyl detector will measure the D-D and D-T neutron yield and the ion temperature of indirect- and direct-drive-implosion experiments. The design of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 31 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…However, trans-stilbene cannot be applied at higher temperature conditions due to a lower melting point (124 • C). Researchers have been working on low-cost crystal growth methods and stilbene alternatives [5][6][7]. Research results from the Lawrence Livermore National Laboratory of America show that 9, 10-diphenylanthracene (DPA) has a higher light yield than stilbene for heavy particles [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…However, trans-stilbene cannot be applied at higher temperature conditions due to a lower melting point (124 • C). Researchers have been working on low-cost crystal growth methods and stilbene alternatives [5][6][7]. Research results from the Lawrence Livermore National Laboratory of America show that 9, 10-diphenylanthracene (DPA) has a higher light yield than stilbene for heavy particles [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…At the National Ignition Facility (NIF), we field an array of nTOF (neutron time of flight) spectrometers [2][3][4][5] and one MRS (magnetic recoil spectrometer) [6,7], sampling the neutron spectrum along very different lines of sight. The pre cision of these NIF neutron spectrometers is better than the approximations Brysk [1] makes in his 1972 paper.…”
Section: Introductionmentioning
confidence: 99%
“…The HENTOF spectrometer consists of a large organic scintillator (e.g. bibenzyl which is used in the current 20 m NTOF spectrometers [194]) positioned 20 m downstream of the LENS. A 'cleanup' collimator reduces the background radiations produced by interactions in the LENS detector system.…”
Section: Future Facility Development and Proposed Nuclear Researchmentioning
confidence: 99%