2012
DOI: 10.1021/bm301125g
|View full text |Cite
|
Sign up to set email alerts
|

Temperature-Induced Ultradense PEG Polyelectrolyte Surface Grafting Provides Effective Long-Term Bioresistance against Mammalian Cells, Serum, and Whole Blood

Abstract: We report a facile method of generating ultradense poly(l-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) surface by using high temperature alone, which in turn provides dramatic improvement in resisting nonspecific bioadsorption. X-ray photoelectron spectroscopy (XPS) revealed that the surface graft density increased ~4 times higher on the surface prepared at 80 °C compared to 20 °C. The studies from small-angle X-ray scattering (SAXS) and the effect of varying ionic strength during/post assemblies at 20 and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
52
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(54 citation statements)
references
References 61 publications
2
52
0
Order By: Relevance
“…In addition, the RGD-functionalized copolymer was unable to strongly enhance the spreading of the cells compared to that observed on a pure PLL- g -PEG coating, perhaps because of low expression levels of RGD-specific integrins in the HEK293 cell line. Although the first issue – the adsorption of spreading-promoting secretion to the PLL backbone – could perhaps be dealt with by creating ultradense PEG-surfaces46, we could not overcome the second problem without genetic engineering. Therefore, we simply excluded the HEK293 cell line from further investigations in which the surface density of the RGD-motif was fine-tuned.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the RGD-functionalized copolymer was unable to strongly enhance the spreading of the cells compared to that observed on a pure PLL- g -PEG coating, perhaps because of low expression levels of RGD-specific integrins in the HEK293 cell line. Although the first issue – the adsorption of spreading-promoting secretion to the PLL backbone – could perhaps be dealt with by creating ultradense PEG-surfaces46, we could not overcome the second problem without genetic engineering. Therefore, we simply excluded the HEK293 cell line from further investigations in which the surface density of the RGD-motif was fine-tuned.…”
Section: Resultsmentioning
confidence: 99%
“…51,52 Prepared FCS/PCS/Gel/EGCG nanoparticles formed at pH 1.2 with pepsin resulted in a matrix structure, and EGCG released from the nanoparticles was 14.8 ± 1.1% at pH 1.2 ( Figure 4). CS, a biodegradable polymer, is known to be a weak base.…”
Section: ■ Discussionmentioning
confidence: 99%
“…In the case of poly(ethylene glycol) (PEG) derivatives the textile substrata were pre-treated with oxygen-plasma [23,24]. The coatings were analyzed for their antimicrobial property by the JIS L 1902:2002.…”
Section: Methodsmentioning
confidence: 99%