2014
DOI: 10.1109/tie.2013.2286576
|View full text |Cite
|
Sign up to set email alerts
|

Temperature Calculation for Tubular Linear Motor by the Combination of Thermal Circuit and Temperature Field Method Considering the Linear Motion of Air Gap

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(16 citation statements)
references
References 25 publications
0
16
0
Order By: Relevance
“…The convection heat resistance R1-7-1, R4-7, R5-7-1, R3-6, R2-3 and R3-4 are calculated as follows [32]…”
Section: Study On Temperature Characteristics Of the Pmecmentioning
confidence: 99%
“…The convection heat resistance R1-7-1, R4-7, R5-7-1, R3-6, R2-3 and R3-4 are calculated as follows [32]…”
Section: Study On Temperature Characteristics Of the Pmecmentioning
confidence: 99%
“…The methods for determining the resistance of linear solenoids (motors) can be divided into two main categories: through thermal analyses [7], [19][20], [28][29][30][31] and from an electrical model [3][4], [33][34]. In the former case, the thermal state inside the actuator is obtained; thus, the resistance of the coil can be computed.…”
Section: Introductionmentioning
confidence: 99%
“…In the former case, the thermal state inside the actuator is obtained; thus, the resistance of the coil can be computed. Considering a linear actuator, the necessary thermal model is obtained by lumped parameter thermal network in [7], [19][20], [28][29] and by (multiphysics) FE (finite element) simulations in [30]. An extended survey on the evolution and on the modern approaches in the thermal analysis of electrical machines is presented in [31].…”
Section: Introductionmentioning
confidence: 99%
“…Combining magnetic reluctance model and thermal resistance network (TRN) model, the non-linearity characteristic of electric machines during healthy and faulty conditions were modelled in [5]. Taking advantages of the flexibility of the thermal circuit method and the accuracy of the temperature field method, the transient temperature-rise of a tubular linear motor with short and movable primary was discussed in [6]. The efficiency of an off-the-shelf 4-kW three-phase line-start permanent-magnet machine (LSPMM) was evaluated as a function of the temperature by both the TRN and practical measurements in [7].…”
Section: Introductionmentioning