Temperature and Weight Dependence of Free Volumes in Conducting Composite Polymer Using Positron Annihilation Techniques

Abstract: Polyvinylidene fluoride-co-hexafluoropropylene (PVdF-co-HFP) with conducting polyaniline (PAni) was studied to measure free-volume intensity (I 3 ), orthopositronium (o-Ps) lifetime ( 3 ), and Doppler momentum distribution parameters (S and W) as a function of temperature varying from 273 to 373 K and PAni weight percentage varying from 1 %-20 % using the techniques of Positron Annihilation Lifetime Spectroscopy (PALS) and Doppler Broadening Annihilation Radiation (DBAR). It has been observed that the free-vol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…In polymers, the expression between the hole free volume size ( υ f ) and the free volume fraction ( f υ ) is given by: where A is the proportionality constant (Tav and Yilmazturk, 2011; Wang et al , 1990). In Figure 7, the o-Ps lifetime (or the hole free volume) and free volume fractions were plotted against the weight percentages of T/M-ND nanocomposites for some temperatures.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In polymers, the expression between the hole free volume size ( υ f ) and the free volume fraction ( f υ ) is given by: where A is the proportionality constant (Tav and Yilmazturk, 2011; Wang et al , 1990). In Figure 7, the o-Ps lifetime (or the hole free volume) and free volume fractions were plotted against the weight percentages of T/M-ND nanocomposites for some temperatures.…”
Section: Resultsmentioning
confidence: 99%
“…The converted signals are sent to a multichannel analyzer (Ortec Model 919E Ethernim MCA) to analyze spectroscopic data by the code of RESOLUTION revealing the lifetime parameters about the free volume in the positron annihilation lifetime spectroscopy (PALS) system (Shakun et al , 2019). The PALS yields two independent parameters as the intensity and the lifetime of o-Ps, related with hole numbers and hole size (or hole free volume), respectively (Jean et al , 2003; Tav and Yilmazturk, 2011).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation