1992
DOI: 10.1016/0584-8547(92)80041-e
|View full text |Cite
|
Sign up to set email alerts
|

Temperature and electron density measurements in a helium/hydrogen capacitively coupled microwave plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1993
1993
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…Many observations made in the present study fit the recently developed understandings of the structure of plasma torch afterglows. Indeed, it is shown here, as it has been elsewhere [23,[47][48][49][50], that the local thermodynamic equilibrium model does not apply, as electrons are far hotter than all other species, and even rotational temperature and excitation temperature are clearly not in equilibrium. Also, the measured rotational temperatures and electron densities are very close to those measured by others [6,23,51,52].…”
Section: Discussionmentioning
confidence: 70%
“…Many observations made in the present study fit the recently developed understandings of the structure of plasma torch afterglows. Indeed, it is shown here, as it has been elsewhere [23,[47][48][49][50], that the local thermodynamic equilibrium model does not apply, as electrons are far hotter than all other species, and even rotational temperature and excitation temperature are clearly not in equilibrium. Also, the measured rotational temperatures and electron densities are very close to those measured by others [6,23,51,52].…”
Section: Discussionmentioning
confidence: 70%
“…The rotational temperatures determined from the OH spectra are in good agreement with temperatures obtained for other plasma spectral sources. They are similar, in their dependence on operating conditions and observation modes, to the rotational temperatures determined in a CMP 27 or in a FAPES source. 28 The rotational temperature values (2150-2760 W) are similar to those measured in a He CMP (1800-3000 K) but higher than those from He FAPES (580-1400 K).…”
Section: Rotational Temperaturesmentioning
confidence: 59%
“…Most work involving the addition of hydrogen has focused on its effect in the ICP. It was recently shown 27,28 that the high thermal conductivity of hydrogen can raise gas-kinetic temperatures in the center of the ICP and can offer a more stable environm ent for viewing analyte emission. An argon/oxygen mixed gas m icrowave plasma was investigated by Kollotzek et al 29 The added oxygen allowed high percentages of methanol to be introduced into the MIP, which made it a suitable detector for high-performance liquid chromatography.…”
Section: Resultsmentioning
confidence: 99%