2007
DOI: 10.2495/bio070281
|View full text |Cite
|
Sign up to set email alerts
|

Techniques of FECG signal analysis: detection and processing for fetal monitoring

Abstract: Fetal heart rate monitoring is a technique for obtaining important information about the condition of a fetus during pregnancy and labor, by detecting the FECG signal generated by the heart of the fetus. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies is becoming a very important requirement in fetal monitoring. The purpose o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 28 publications
0
15
0
Order By: Relevance
“…The architecture of the neural network is designed mainly by using the adaptive filtering approach that is the combination of ADALINE (adaptive linear network) and TDL (tapped delay line) which was described in detail in our previous work [11] shown in Fig.1. Our previous work was mainly on the signal processing algorithm for FECG extraction only but this article is about the hardware prototyping of that algorithm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The architecture of the neural network is designed mainly by using the adaptive filtering approach that is the combination of ADALINE (adaptive linear network) and TDL (tapped delay line) which was described in detail in our previous work [11] shown in Fig.1. Our previous work was mainly on the signal processing algorithm for FECG extraction only but this article is about the hardware prototyping of that algorithm.…”
Section: Methodsmentioning
confidence: 99%
“…Fig.1. Adaptive Filter Network [11] The MECG, which is predicted and close to the AECG, passes through the one (N -1, were N = 2) tapped delay line. The tapped delay line was considered mainly due to lower complexity and modeling of FPGA.…”
Section: Methodsmentioning
confidence: 99%
“…21 ___________________________________________ and has a superimposed 60Hz component. The transition may occur only once or may rapidly occur several times in succession [5]. Motion Artifact: When motion artifact is introduced to the system, the information is skewed.…”
Section: Interfaces and Noises Affecting The Ecg Signalmentioning
confidence: 99%
“…The surfaces of the human bodies are constantly inundated with electric-magnetic radiation and it is virtually impossible to avoid exposure to ambient noise on the surface of earth [5].…”
Section: Interfaces and Noises Affecting The Ecg Signalmentioning
confidence: 99%
See 1 more Smart Citation