2009
DOI: 10.1117/12.811143
|View full text |Cite
|
Sign up to set email alerts
|

System for definition of the central-chest vasculature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2010
2010
2012
2012

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…To this end, we have used the LNSM to perform a detailed quantitative study of the lymph nodes depicted in our database [38,45, 47]. In addition, we have performed studies to determine the ability of both radiologists and pulmonologists to identify lymph nodes in MDCT, and we have made early efforts to apply the LNSM to planning follow-on staging bronchoscopy [24,4850]. …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To this end, we have used the LNSM to perform a detailed quantitative study of the lymph nodes depicted in our database [38,45, 47]. In addition, we have performed studies to determine the ability of both radiologists and pulmonologists to identify lymph nodes in MDCT, and we have made early efforts to apply the LNSM to planning follow-on staging bronchoscopy [24,4850]. …”
Section: Discussionmentioning
confidence: 99%
“…In particular, for the set (1), we compute the segmented airway tree using the methods of [22,25], we compute the three sections of the aorta, aorta centerline, and PA using the methods of [27,28], and methods for segmenting the lungs, sternum, and spine appear in [22,24]. References [20,21] describe the methods for airway endoluminal surface definition, while [29] describes the centerline method.…”
Section: Methodsmentioning
confidence: 99%
“…penalize high bending (note that curvature is the reciprocal of the radius of curvature), with r min being the minimum pulmonary artery radius found during Hough transform, as it is impossible for the pulmonary artery to have a smaller radius of curvature than its own radius. Compared to previous work, 2,11,15 where one or more models need to be fitted globally as well as locally using several energy terms, we here greatly reduce the amount and complexity of optimizations to a single local minimization, making the approach faster and stable.…”
Section: Nurbs Fittingmentioning
confidence: 99%
“…five to eight user selected landmarks 12 or a manually placed seed point 13 ), or fail for up to 20% of cases, 2,11 as the utilized fixed model or models are not flexible enough. We here present the first work that addresses these problems: Using an adaptive model, it works equally well on a large number of contrast enhanced and non-contrast data sets.…”
Section: Related Workmentioning
confidence: 99%
“…The publications can be mainly categorized into detection [12,13,14,15,16] and segmentation [17,18,19,20,21,22,23,24] of lymph nodes, labeling of lymph node stations [25,26], and computer assisted treatment planning [27]. For the segmentation of lymph nodes, recently also a commercial system has been announced [28].…”
Section: Introductionmentioning
confidence: 99%