1981
DOI: 10.1109/tns.1981.4331148
|View full text |Cite
|
Sign up to set email alerts
|

System Design of Fast Pet Scanners Utilizing Time-of-Flight

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
18
0

Year Published

1989
1989
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(19 citation statements)
references
References 7 publications
1
18
0
Order By: Relevance
“…Time of flight PET (ToF-PET) is an advance over traditional PET that exploits the time difference Δt in detection of the two photon events and correlates it to the position Δx of the annihilation point with respect to the center of the field of view (FoV) according to the formula (Figure 2) [2]: Δx=cΔt2Even though the concept of ToF PET and its implementation in PET system designs started in the early 1980’s [3], the development of new fast scintillation materials and the rapid advances in photo-detection technology have recently led to increased interest in the development of novel ToF-PET detector designs as well as to commercialization of the first ToF-PET clinical systems (Section 3).…”
Section: Introductionmentioning
confidence: 99%
“…Time of flight PET (ToF-PET) is an advance over traditional PET that exploits the time difference Δt in detection of the two photon events and correlates it to the position Δx of the annihilation point with respect to the center of the field of view (FoV) according to the formula (Figure 2) [2]: Δx=cΔt2Even though the concept of ToF PET and its implementation in PET system designs started in the early 1980’s [3], the development of new fast scintillation materials and the rapid advances in photo-detection technology have recently led to increased interest in the development of novel ToF-PET detector designs as well as to commercialization of the first ToF-PET clinical systems (Section 3).…”
Section: Introductionmentioning
confidence: 99%
“…It prompts also a development of better PMTs, which will assure the ultimate time resolution with new heavy crystals to be below 500 ps for the future TOF PET scanners, recognized as a limit for TOF PET [1]. The first TOF PETs [4,5] proposed in the early 1980s were not successful because of a low stopping power of BaF 2 crystals for annihilation quanta. LSO in this respect is very promising [1].…”
Section: Introductionmentioning
confidence: 99%
“…During the 1980s different PET systems with TOF information were developed [2][3][4]. The scintillators (primarily BaF 2 ) had low stopping power and low light.…”
Section: Tof-pet Systemsmentioning