2020
DOI: 10.1016/j.msec.2020.111159
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and characterization of PCL-DA:PEG-DA based polymeric blends grafted with SMA hydrogel as bio-degradable intrauterine contraceptive implant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 37 publications
1
10
0
Order By: Relevance
“…The estrogen and progesterone are encapsulated in PCL, and the intrauterine contraceptive device with a shape that can be adapted to the body's structure is prepared by fused deposition modeling. As a linearly synthesized degradable aliphatic polyester, PCL possesses high mechanical strength, plasticity, biocompatibility, and low degradation rate, while its degradation products are completely metabolized by the tricarboxylic acid cycle or directly excreted by the kidneys, which makes it suitable for long-term carrier implantation in vivo [ 28 , 116 ]. In addition, PCL has been approved by the U.S. FDA for drug delivery system applications with a good drug delivery structure and stable drug release rate [ 9 ].…”
Section: Advanced Biomaterials For Contraception By Various Routesmentioning
confidence: 99%
See 4 more Smart Citations
“…The estrogen and progesterone are encapsulated in PCL, and the intrauterine contraceptive device with a shape that can be adapted to the body's structure is prepared by fused deposition modeling. As a linearly synthesized degradable aliphatic polyester, PCL possesses high mechanical strength, plasticity, biocompatibility, and low degradation rate, while its degradation products are completely metabolized by the tricarboxylic acid cycle or directly excreted by the kidneys, which makes it suitable for long-term carrier implantation in vivo [ 28 , 116 ]. In addition, PCL has been approved by the U.S. FDA for drug delivery system applications with a good drug delivery structure and stable drug release rate [ 9 ].…”
Section: Advanced Biomaterials For Contraception By Various Routesmentioning
confidence: 99%
“…However, the only one case was the majority of the embolic agent immediately extruded from the oviduct into the uterus, and histological analysis showed varying degrees of occlusion, fibrosis, and inflammation. Subramanian et al represented an innovative insight into the use of a hydrogel formulation composed of styrene-cis-butylene-based styrene maleic anhydride (SMA) dissolved in dimethyl sulfoxide (DMSO) to make a non-hormonal tubal contraceptive implant [ 129 ]. Polymeric hydrogels cause sperm inactivation by lowering the pH of the surrounding environment to disrupt the acrosome.…”
Section: Advanced Biomaterials For Contraception By Various Routesmentioning
confidence: 99%
See 3 more Smart Citations