2016
DOI: 10.1002/jssc.201501301
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis and application of a nanoporous ion-imprinted polymer for the separation and preconcentration of trace amounts of vanadium from food samples before determination by electrothermal atomic absorption spectrometry

Abstract: A vanadium ion-imprinted polymer was synthesized in the presence of V(V) and N-benzoyl-N-phenyl hydroxyl amine using 4-vinyl pyridine as the monomer, ethylene glycol dimethacrylate as the cross linker and 2,2'-azobis(isobutyronitrile) as the initiator. The imprinted V(V) ions were completely removed by leaching the polymer with 5 mol/L nitric acid, and the polymer structure was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The ion-imprinted polymer was used as the s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 38 publications
(41 reference statements)
0
6
0
Order By: Relevance
“…Moreover, a vanadium ion‐imprinted polymer (IIP) was reported for SPE and electrothermal AAS determination of V(V) in parsley, zucchini, black tea, rice, and water samples [109].…”
Section: Applications Of Molecularly Imprinted Polymer‐based Spe To Rmentioning
confidence: 99%
“…Moreover, a vanadium ion‐imprinted polymer (IIP) was reported for SPE and electrothermal AAS determination of V(V) in parsley, zucchini, black tea, rice, and water samples [109].…”
Section: Applications Of Molecularly Imprinted Polymer‐based Spe To Rmentioning
confidence: 99%
“…Different analytical instruments such as inductively coupled plasma atomic emission spectrometry (ICP-AES) [3,4], electrothermal atomic absorption spectroscopy (ETAAS) [5][6][7][8], and inductively coupled plasma mass spectrometry (ICP-MS) [9,10] have been reported for determination of metal ions. ICP-AES has limits of detection (LODs) in the ppt (ng L -1 ) to ppb (μg L -1 ) range.…”
Section: Introductionmentioning
confidence: 99%
“…Various sample pretreatment methods such as cloud point extraction (CPE) [4], co-precipitation [11], liquidliquid extraction (LLE) [6], and solid-phase extraction (SPE) [7,12] have been used to preconcentrate metal ions and eliminate matrix effects. Some advantages of the SPE technique such as the short extraction time, low consumption of organic solvents, and adsorbents have resulted in the wide applications of this method for extraction of various organic and inorganic pollutants [13].…”
Section: Introductionmentioning
confidence: 99%
“…The obtained polymer, ion‐imprinted polymer, can recognize template ions with high selectivity. Due to its stability, reusability, and selectivity to target ions [1], IIP has been widely used in enrichment and separation of metal ions [2–4], especially in the fields of membranes [5] and SPE [6–8]. In addition, not only can IIP be used to extract uranium from seawater [9], but it also plays an important role in radioactive protection [10] and preparation of radionuclide [11], which is of great significance in the development of radiochemistry.…”
Section: Introductionmentioning
confidence: 99%