2014
DOI: 10.1002/mrm.25453
|View full text |Cite
|
Sign up to set email alerts
|

Susceptibility‐based positive contrast MRI of brachytherapy seeds

Abstract: The results show that the proposed method provides positive contrast for the seeds and correctly differentiates them from other structures that appear similar to the seeds on conventional magnitude images.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
44
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 29 publications
(44 citation statements)
references
References 31 publications
0
44
0
Order By: Relevance
“…37 Other means of improving the detection accuracy of GFM could be by magnetic susceptibility mapping or by providing positive contrast in the vicinity of the marker using off-resonance signals. [29][30][31][32]47 As MEGRE is a generic and available sequence on multiple vendor platforms this should be further explored for both automatic and manual GFM identification.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…37 Other means of improving the detection accuracy of GFM could be by magnetic susceptibility mapping or by providing positive contrast in the vicinity of the marker using off-resonance signals. [29][30][31][32]47 As MEGRE is a generic and available sequence on multiple vendor platforms this should be further explored for both automatic and manual GFM identification.…”
Section: Discussionmentioning
confidence: 99%
“…27,28 The use of more exotic sequences to even enable a positive contrast of the metal has been developed. [29][30][31][32] The use of multiple dedicated MRI sequences for prostate RTP is common. The proposed MRI only workflows for EBRT of prostate present in the literature all depend on separate MRI sequences for GFM identification, target delineation, and sCT generation.…”
Section: Introductionmentioning
confidence: 99%
“…The co‐RASOR (center‐out radial sampling with off‐resonance reception) method was proposed to shift local signal pile‐ups caused by off‐resonance back to the center of the brachytherapy seed in radial acquisitions . Dong et al applied susceptibility gradient mapping to specifically use the local dephasing around brachytherapy seeds to generate positive contrast at the location of the seed . Since these two approaches are based on local susceptibility effects, they are less sensitive to other field inhomogeneities.…”
Section: Introductionmentioning
confidence: 99%
“…By taking advantage of the seeds' high magnetic susceptibility, recent efforts in seed visualization on MRI images include the use of an inversion-recovery with ONresonant water suppression (IRON) prepulse to spectrally select off-resonant protons, 20 the use of ultrashort-TE sequences to preserve signal before rapid transverse dephasing, 21 the postprocessing use of homodyne high-pass filters of various sizes, 22,23 the use of susceptibility gradient mapping using the original resolution (SUMO) by filtering in k-space, 24 the use of a kernel deconvolution algorithm with regularized L 1 minimization 25 (the dipole kernel 26 and a nominal seed kernel 27 have been explored), as well as the use of centerout radial sampling with off-resonance reception (co-RASOR) that moves the radial signal pile-up to the seed's center (using multiple acquisitions 28 and only a single acquisition 29 ). However, imaging susceptibility may be inconsistent across MRI slices, difficult to locate accurately, and more challenging in heterogeneous tissue.…”
mentioning
confidence: 99%
“…23 Ultimately, MRI-only postimplant dosimetry allows for superior soft tissue contouring, no extraneous radiation dose, image-acquisition flexibility, and possible integration of functional imaging. Regardless of whether MRI-only postimplant dosimetry is achieved using markers 6 or the other solutions [18][19][20][21][22][23][24][25][26][27][28][29] described above, the next step is to explore the impact of MRI soft tissue contrast on the accuracy and precision of anatomical contouring on patient images, so as to examine the correlation of dose deposited in the prostate and normal tissue to tumor control and normal tissue complications. Ultimately, in future patient studies comparing MRI-only to MRI-CT fusion-based postimplant dosimetry, we need to evaluate the improvements in the accuracy and precision of contouring prostate and organs at risk, the accuracy and precision of seed localization, as well as the subsequent accuracy and precision of dose volume histogram parameters, apart from accounting from fusion uncertainties.…”
mentioning
confidence: 99%