2017
DOI: 10.1002/mp.12505
|View full text |Cite
|
Sign up to set email alerts
|

Challenges in MR‐only seed localization for postimplant dosimetry in permanent prostate brachytherapy

Abstract: Purpose: An MR-only postimplant dosimetry workflow for low dose rate (LDR) brachytherapy could reduce patient burden, improve accuracy, and improve cost efficiency. However, localization of brachytherapy seeds on MRI scans remains a major challenge for this type of workflow. In this study, we propose and validate an MR-only seed localization method and identify remaining challenges. Methods and materials: The localization method was based on template matching of simulations of complex-valued imaging artifacts … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
18
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(18 citation statements)
references
References 29 publications
0
18
0
Order By: Relevance
“…There have been a number of studies investigating dedicated MRI sequences for fiducial detection . Both balanced steady‐state free precession sequences and sequences based on spoiled gradient‐echoes have been employed in 2D and 3D acquisitions, relying on T2*‐related signal loss to create a detectable signal void in the vicinity of the fiducials. The averaging of consecutive echoes in multi‐echo recalled sequences, such as the one used here is an attractive mechanism to increase the signal‐to‐noise ratio.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There have been a number of studies investigating dedicated MRI sequences for fiducial detection . Both balanced steady‐state free precession sequences and sequences based on spoiled gradient‐echoes have been employed in 2D and 3D acquisitions, relying on T2*‐related signal loss to create a detectable signal void in the vicinity of the fiducials. The averaging of consecutive echoes in multi‐echo recalled sequences, such as the one used here is an attractive mechanism to increase the signal‐to‐noise ratio.…”
Section: Discussionmentioning
confidence: 99%
“…Studies so far for similar sequences have focused on accuracy of fiducial detection . In this article we examine the T2*W sequence and investigate whether it is possible to use this sequence alone in prostate studies, considering geometric integrity, the ability to locate marker positions and the ability to provide enough contrast for prostate volume outlining.…”
Section: Introductionmentioning
confidence: 99%
“…The first is MRI‐based seed localization. Metallic seeds do not generate signal intensity using conventional pulse sequences, so appear as signal voids leading to some nonseed features identified as seeds (false positives) and some missing seeds (false negatives) . Seeds designed to generate positive contrast have been demonstrated, but are not typically integrated with isotopes used for therapy .…”
Section: Introductionmentioning
confidence: 99%
“…Metallic seeds do not generate signal intensity using conventional pulse sequences, so appear as signal voids leading to some nonseed features identified as seeds (false positives) and some missing seeds (false negatives). 14,15 Seeds designed to generate positive contrast have been demonstrated, but are not typically integrated with isotopes used for therapy. 16 Balanced steady-state free precession (bSSFP) pulse sequences can improve MRI quality for seed identification 17 and susceptibility-based pulse sequences have been developed to provide positive contrast with conventional seeds.…”
Section: Introductionmentioning
confidence: 99%
“…Zijlstra et al have studied the feasibility of a template-matching algorithm that uses the simulated magnetic field distortions around the seeds as the template to match with those in patients; although the proposed method has acceptable performance in detection of spaced seeds (average error of 0.8 AE 0.4 mm), one-third of nonspaced or clumped seeds were not correctly identified. 10 Martin et al have compared the MRI-only LDR postimplant dosimetry (using stranded seeds with cobaltdichloride-N-acetyl cysteine [C4] MR-markers as spacers) to the standard MR-CT fusion-based approach. 11,12 They have demonstrated that MRI-only dosimetry using C4 MR markers is feasible and accurate; however, there are some limitations associated with C4 application such as higher cost compared with conventional seeds, the necessity of endorectal coil for marker visualization, and nonapplicability to plans with nonspaced or loose seeds.…”
mentioning
confidence: 99%