2010
DOI: 10.1007/s11548-010-0511-y
|View full text |Cite
|
Sign up to set email alerts
|

Surgical stent planning: simulation parameter study for models based on DICOM standards

Abstract: A standards-based general simulation model for optimizing stent-graft selection may be feasible. At present, there are limitations due to specification of individual vessel material parameters and for simulating the proximal fixation of stent-grafts with hooks. Simulation data with clinical relevance for documentation and presentation can be stored using existing or new DICOM extensions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…The elastic recoil of the stent reduced its radial strength by 18.75%. However, smaller radial strength might lead to the migration of the stent [28]. In contrast, the recoil relieved the peak arterial stresses by 38.51% as well as the percentage area of high stress (>80 kPa) by 10.14% (Fig.…”
Section: Discussionmentioning
confidence: 94%
“…The elastic recoil of the stent reduced its radial strength by 18.75%. However, smaller radial strength might lead to the migration of the stent [28]. In contrast, the recoil relieved the peak arterial stresses by 38.51% as well as the percentage area of high stress (>80 kPa) by 10.14% (Fig.…”
Section: Discussionmentioning
confidence: 94%
“…Other applications of finite element simulations have been proposed, for the placement of a stent in the context of EVAR procedures 22 , or in the peripheral vessels [23][24][25][26][27] .…”
Section: Discussionmentioning
confidence: 99%
“…While simulation-based analysis on the interaction of the wire stent (for the treatment of stenosis) and the vessel wall had been carried out by several research teams [6][7][8][9][10], only two relevant papers on the numerical description of the mechanical behavior of a stent graft with Nitinol rings have been detected so far [11,12]. By means of a simplified model, Kleinstreuer et al analyzed the effects of different material combinations of the stent graft regarding fatigue resistance, radial forces and flexibility.…”
Section: Introductionmentioning
confidence: 99%
“…Blood pressure, consistency of intima and the existence of plaque were found to be influential parameters for the representation of the interaction between stent graft and vessel. Furthermore, the choice of the respective material models was presented [12]. The fixing force of the stent graft, as well as the contact pressure of the stent ring towards vessel wall and plaque have also been detected as helpful output variables for the optimization of implant selection.…”
Section: Introductionmentioning