2007
DOI: 10.1510/icvts.2007.152298
|View full text |Cite
|
Sign up to set email alerts
|

Surgical removal of an embolised patent ductus arteriosus amplatzer occluding device in a 4-year-old girl

Abstract: Alternative strategy of non-surgical closure of patent ductus arteriosus (PDA) is presently the first line of therapy. Several devices are being used for transcatheter closure of PDA. A four-year-old girl underwent a second attempt at PDA closure with an amplatzer device. However, after the deployment of the device it got dislodged into the right pulmonary artery hilum. Several attempts by catheter retrieval failed. The girl underwent surgical removal of the device which was complicated by pulmonary artery inj… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0
1

Year Published

2009
2009
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 9 publications
0
14
0
1
Order By: Relevance
“…These include systemic or pulmonary embolization, hemolysis, residual shunts, hemorrhaging after removing the vascular access, and stenosis of the pulmonary artery (10,11,19).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…These include systemic or pulmonary embolization, hemolysis, residual shunts, hemorrhaging after removing the vascular access, and stenosis of the pulmonary artery (10,11,19).…”
Section: Discussionmentioning
confidence: 99%
“…To date, many device dislocation have been reported, most of them noticed during the intra-operative and immediate post-operative period (1,19,21). In human medicine, 6 (2), 8 (11) and 12 (10) months after the PDA closure procedure, late device displacement was reported for reasons still unknown.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…• Transkateter yolla PDA kapatmada karşılaşılabilecek komplikasyonlar Transkateter yolla PDA kapatma işlemi etkili ve güvenli olmasına rağmen, bazı hastalarda cihaz embolizasyonu, rezidüel defekti olanlarda şiddetli hemoliz, duktusta rekanalizasyon, sol pulmoner arter ve inen aortaya cihazın protrüzyonu gibi komplikasyonlar görülebilir (57,(58)(59)(60)(61). Operatör duktusun boyutlarını ölçerken dikkatli ve titiz davranmadığında, ayrıca cihazın kalibrasyonunu doğru yapamadığında, uygun olmayan cihaz seçiminde ve ağır pulmoner hipertansiyon varlığında embolizasyon riski ve cihaz protrüzyonu gibi sorunlar meydana gelebilir.…”
Section: Ayrıcı Tanıunclassified
“…There was one death as a result of this last complication. 11 Migration of devices placed in the heart is usually diagnosed as a result of clinical suspicion combined with an echocardiogram that shows that the Amplatzer  device is no longer present. The device is located systemically using angiotomography.…”
Section: Description Of the Casementioning