2017
DOI: 10.21521/mw.5649
|View full text |Cite
|
Sign up to set email alerts
|

Late Amplatzer device displacement after percutaneous PDA embolization: case description.

Abstract: A 6-month-old, 17 kg, male Labrador Retriever was presented for an evaluation of a suspected patent ductus arteriosus (PDA). Transthoracic echocardiography confirmed a left-to-right shunting PDA with a minimal ductal diameter of 3.5 mm. A transcatheter PDA occlusion was performed, and a 16 mm Amplatzer Vascular Plug II was selected for the procedure. Within 13 days of discharge, the dog developed sudden lethargy, tachypnea, and coughing after physical activity. Thoracic radiographs showed the Amplatzer device … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…The order of prevalence of these defects is related to the dog breed population in a particular geographical region. Publications in Poland have described single cases of CHD (6,7), prevalence of aortic stenosis (15), tricuspid dysplasia (17), and tetralogy of Fallot (16), and a description of treatment of pulmonic stenosis (19). A large-scale study of the number and types of congenital heart defects in Poland has not been published to date.…”
Section: Praca Oryginalnamentioning
confidence: 99%
“…The order of prevalence of these defects is related to the dog breed population in a particular geographical region. Publications in Poland have described single cases of CHD (6,7), prevalence of aortic stenosis (15), tricuspid dysplasia (17), and tetralogy of Fallot (16), and a description of treatment of pulmonic stenosis (19). A large-scale study of the number and types of congenital heart defects in Poland has not been published to date.…”
Section: Praca Oryginalnamentioning
confidence: 99%
“… 2 , 6 , 31 Postoperative device embolization is described rarely in dogs after PDA occlusion using Gianturco coils 6 , 16 , 42 as well as with ACDO 2 in the first 24 hours after intervention. Delayed embolization in the following days to weeks is described rarely in case reports in dogs with ACDO, 43 AVP‐II, 44 and AVP‐IV 36 and often associated with severe cardiorespiratory compromise. 43 , 44 …”
Section: Discussionmentioning
confidence: 99%
“…Delayed embolization in the following days to weeks is described rarely in case reports in dogs with ACDO, 43 AVP‐II, 44 and AVP‐IV 36 and often associated with severe cardiorespiratory compromise. 43 , 44 …”
Section: Discussionmentioning