2014
DOI: 10.1590/1807-2577.1049
|View full text |Cite
|
Sign up to set email alerts
|

Surface roughness and hardness of yttria stabilized zirconia (Y-TZP) after 10 years of simulated brushing

Abstract: Introduction: The Y-TZP zirconia used for prosthetic infrastructure, in some clinical situations, can be exposed to the oral environment. In these situations, a polished surface without changes is extremely important. Objective: The aim of this study was to evaluate the mean roughness (Ra) and Vickers hardness of Y-TZP zirconia (Lava™) after simulating ten years of brushing. Material and method: Thirty-six Y-TZP bar-shaped specimens (20mm X 4mm X 1.2mm) were divided into three groups: storage in distilled … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 20 publications
1
9
0
Order By: Relevance
“…(26,27) Brushing effects on the surface properties of dental materials were evaluated in the study using simulated tooth brushing abrasion test, which is considered a typical model in the literature. (28,29) The load of brushing application in the present study was (300 g) that is near to the range of clinical application and consistent with other studies (200 g to 350 g). (30)(31)(32) The discussion regarding how much Ra values that considered clinically acceptable are controversial opinions in the literature, however, Ra values after brushing with conventional dentifrice in the present study is agreed with another study & were clinically acceptable where it presents within the Ra range from 0.25 um to 0.5um, which is undetectable clinically by the tongue.…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…(26,27) Brushing effects on the surface properties of dental materials were evaluated in the study using simulated tooth brushing abrasion test, which is considered a typical model in the literature. (28,29) The load of brushing application in the present study was (300 g) that is near to the range of clinical application and consistent with other studies (200 g to 350 g). (30)(31)(32) The discussion regarding how much Ra values that considered clinically acceptable are controversial opinions in the literature, however, Ra values after brushing with conventional dentifrice in the present study is agreed with another study & were clinically acceptable where it presents within the Ra range from 0.25 um to 0.5um, which is undetectable clinically by the tongue.…”
Section: Discussionsupporting
confidence: 91%
“…(33) The Ra values obtained in this study disagree and differ from the values obtained in other studies in which the Ra values ranged from 0.18 to 0.98 um. (28,34) In the present study different kinds of ceramic blocks (Zirconia, e.max, Vita enamic & Lava ultimate) were used to include different classification of ceramics as possible. Roughness values (Ra) is different in all kinds of ceramics tested in the study resulting different wear pattern of each type of ceramics, that is closely influenced by microstructure and physical characteristics of ceramic type, specifically hardness, flexural strength and fracture toughness.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Ra values obtained from the specimens used in this study agree with the values obtained in other studies in which the Ra values ranged from 0.18 to 0.98 mm. 15,25,37 No significant changes were found after immersion (control, SW group) and brushing with water (BW group). However, Ra values increased after brushing with conventional dentifrice (BD group), and there was a polishing effect on surfaces that were brushed with whitening dentifrice (BWD group).…”
Section: Discussionmentioning
confidence: 95%
“…The specimens were brushed using a linear brushing machine (Mavtec Comércio e Serviços) equipped with soft bristle toothbrush heads (#35, Oral-B Indicator; Procter & Gamble Brazil S/A) using distilled water (BW), conventional fluoride dentifrice slurry (BD), or whitening dentifrice slurry (BWD). The machine was set to brush at a rate of 60 reciprocal strokes per minute, with a vertical load of 0.98 N 32,37 for 244 hours. 27 Slurries of dentifrice were prepared by mixing 2 parts of distilled water (mL) and 1 part of dentifrice (g) 38 in a magnetic mixer for 10 minutes.…”
Section: Methodsmentioning
confidence: 99%