2021
DOI: 10.1016/j.rinp.2021.104613
|View full text |Cite
|
Sign up to set email alerts
|

Surface pre-treatments of Ti-Nb-Zr-Ta beta titanium alloy: The effect of chemical, electrochemical and ion sputter etching on morphology, residual stress, corrosion stability and the MG-63 cell response

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 72 publications
0
8
0
Order By: Relevance
“…The features of a spacing parameter are depended on the number of peaks and valleys regions. Some pores, scratches and small dimples presence on the surface; this can be attributed to the some defects that probably originate from random heterogeneity of the material as observed by Petr Vlcak et al when they study the morphology of Ti-Nb-Zr-Ta alloy by AFM [17].…”
Section: Surface Topographymentioning
confidence: 82%
“…The features of a spacing parameter are depended on the number of peaks and valleys regions. Some pores, scratches and small dimples presence on the surface; this can be attributed to the some defects that probably originate from random heterogeneity of the material as observed by Petr Vlcak et al when they study the morphology of Ti-Nb-Zr-Ta alloy by AFM [17].…”
Section: Surface Topographymentioning
confidence: 82%
“…On the treated Zr sample, only zirconium oxides were detected. The zirconium (Zr 3d 5/2) nitride peak should be detected at an energy of 180.9 eV [ 17 ]. In numerous works [ 22 , 23 , 24 , 25 , 26 , 27 ], zirconium alloys were treated by nitrogen ion implantation at higher temperatures than in our work, usually between 300 °C and 800 °C, and had successfully detected zirconium nitride on their samples.…”
Section: Resultsmentioning
confidence: 99%
“…As stated before, there is concern regarding the wear resistance of the oxide layer. This is where nitrogen ion implantation can be helpful [ 5 , 7 , 8 , 11 , 12 , 13 , 14 , 15 , 16 , 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…Potentiodynamic polarization curves were measured from À 1.0 V to 1.0 V (versus saturated calomel electrode) in the anodic direction with a scan rate of 1 mV/s. These similar or narrower potential ranges of potentiodynamic tests were usually used for the determination of corrosion performances of metal materials [26][27][28]. Corrosion parameters, including corrosion potential and corrosion current density extracted from potentiodynamic polarization curves, were used to evaluate the corrosion resistance in a simulated body fluid, Ringer's solution.…”
Section: Film-substrate Adhesion and Corrosion Behavior Testingmentioning
confidence: 99%