2015
DOI: 10.1049/el.2015.2276
|View full text |Cite
|
Sign up to set email alerts
|

Surface plasmon resonance sensor based on hollow‐core PCFs filled with silver nanowires

Abstract: A surface plasmon resonance (SPR) sensor based on hollow-core photonic crystal fibre (HC-PCF) filled with silver nanowires is designed. The analyte and silver nanowires are full filled in the air holes of the HC-PCF to realise the SPR sensing, which is more convenient than silver coated in operation. The designed sensor is analysed through numerical simulations and demonstrated by experiments. All the results show that a blue-shift is obtained with increase of the analyte refractive index (RI), and the silver … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
21
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 59 publications
(21 citation statements)
references
References 11 publications
(11 reference statements)
0
21
0
Order By: Relevance
“…This limits the practical implementation of PCF SPR sensors. To eliminate the thin film coating, nanowire based PCF SPR sensors have been reported [56,[116][117][118]. A silver nanowire based PCF SPR sensor has been reported for the RI detection, where the nanowires and liquid were selectively filled 1 st ring of the PCF [116].…”
Section: Internally Metal Film Coated Pcf Spr Sensorsmentioning
confidence: 99%
See 3 more Smart Citations
“…This limits the practical implementation of PCF SPR sensors. To eliminate the thin film coating, nanowire based PCF SPR sensors have been reported [56,[116][117][118]. A silver nanowire based PCF SPR sensor has been reported for the RI detection, where the nanowires and liquid were selectively filled 1 st ring of the PCF [116].…”
Section: Internally Metal Film Coated Pcf Spr Sensorsmentioning
confidence: 99%
“…Blue shift occurred due to the increase in temperature with a sensitivity of 2.7 nm/°C. Hollow-core PCF has been experimentally developed for the RI detection, where the core is filled with liquid and silver nanowires ( Figure 3f) [118], resulting in wavelength sensitivity of 14,240 nm/RIU. Furthermore, hollow-core photonic band gap fiber (HC-PBGF) based SPR sensor was numerically investigated where the core was filled with liquid and silver nanowires ( Figure 3g) [119].…”
Section: Internally Metal Film Coated Pcf Spr Sensorsmentioning
confidence: 99%
See 2 more Smart Citations
“…1 . More recently, chip-scale photonic devices have also been used in such applications 2 , including localized surface plasma [3][4][5] , photonic crystals [6][7][8] , micro-cavities 9,10 , waveguides [11][12][13][14] , interferometers [15][16][17] , and nano-fibers [18][19][20][21] . The intrinsic mechanism of RI sensor is detecting the parameters which are determined by diffraction characteristics changing due to the varieties of cladding RI of sensors.…”
Section: Introductionmentioning
confidence: 99%