2017
DOI: 10.1109/tpel.2016.2542140
|View full text |Cite
|
Sign up to set email alerts
|

Suppression of Time-Varying Interharmonics Produced by Medium-Frequency Induction Melting Furnaces by a HAPF System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
31
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 24 publications
(32 citation statements)
references
References 39 publications
0
31
0
1
Order By: Relevance
“…The use of active filters has been suggested and a method extracting each harmonic and interharmonic current reference with 5 Hz resolution has been proposed in [6,7] by using multiple synchronous reference frame (MSRF) technique. Active power filters (APF) have been a hot research topic for nearly three decades due to their superiorities to passive harmonic filters [10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28]. There are various APF types, summarized in [10], and they are classified with respect to their circuit topology and application area.…”
Section: Problem Definitionmentioning
confidence: 99%
See 4 more Smart Citations
“…The use of active filters has been suggested and a method extracting each harmonic and interharmonic current reference with 5 Hz resolution has been proposed in [6,7] by using multiple synchronous reference frame (MSRF) technique. Active power filters (APF) have been a hot research topic for nearly three decades due to their superiorities to passive harmonic filters [10][11][12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28]. There are various APF types, summarized in [10], and they are classified with respect to their circuit topology and application area.…”
Section: Problem Definitionmentioning
confidence: 99%
“…The most basic and effective waveform modulation technique for generating a current reference with a voltage source converter is to use hysteresis band modulation philosophy [38][39][40][41][42][43][44]. The hysteresis band modulation technique has been widely used in the literature for APF systems [25,43,44] due to its advantages, like easy implementation, dynamic stability, controllability on current, and perfect tracking of the reference signal [25,44]. However, it has also some drawbacks like high and varying switching frequency, thus high switching losses [25,44].…”
Section: Proposed Control Strategymentioning
confidence: 99%
See 3 more Smart Citations