2016
DOI: 10.1109/tpwrd.2016.2520958
|View full text |Cite
|
Sign up to set email alerts
|

Supervisory Protection and Automated Event Diagnosis Using PMU Data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
58
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(61 citation statements)
references
References 11 publications
0
58
0
Order By: Relevance
“…Moreover, the accuracy of an FL can be improved by applying synchronized measurements of currents or voltages. Until now, many faults have been detected by PMUs in distribution systems [72][73][74][75][76][77][78]. However, some FL methods use only current or voltage phasors [79,80].…”
Section: Fault Detection and Locationmentioning
confidence: 99%
“…Moreover, the accuracy of an FL can be improved by applying synchronized measurements of currents or voltages. Until now, many faults have been detected by PMUs in distribution systems [72][73][74][75][76][77][78]. However, some FL methods use only current or voltage phasors [79,80].…”
Section: Fault Detection and Locationmentioning
confidence: 99%
“…Therefore the quality of synchrophasor measurements from PMUs, including timing accuracy, has also been a key topic of research, particularly in Europe [7] and the USA [8], [9]. Research work has highlighted the challenges associated with: measurement quality, which is very important for distribution system applications of PMUs; PMU data quality; PMU timing accuracy [10]; real-time supervisory assessment of multiple PMU data streams [11]; and latency [12]. The importance of rigorous testing of PMU-based systems is strongly emphasized in [13] and analysis of the large-scale PMU data quality issues is given in [14].…”
Section: A Overview Of Measurement Challengesmentioning
confidence: 99%
“…PMUs are used to get the voltage and current measurements from different buses for approximating a voltage stability indicator in near real time. Some recent PMU based applications for voltage stability are summarized in Table 3 [36][37][38][39][40][41][42][43][44][45][46][47][48][49][50][51][52].…”
Section: ) Voltage Stability Monitoringmentioning
confidence: 99%
“…In second, PMU data is analyzed for most prominent disturbance signature. PMU data is fed to the strongest signal selection and fault detection (SSFD) module which preprocesses the signals by removing bad data and identify the data stream with the highest strength [48,49] An adaptive PMU based protection scheme for both transposed and untransposed parallel transmission lines which is based on the distributed line model and the synchronized phasor measurements at both ends of lines is discussed [50] Another adaptive wide area backup protection scheme for transmission lines is proposed in which backup protection zones are formed based on PMU placement and network topology. It also provides a non-iterative solution for the faulted line and FL identification problem [51,52] SSE estimates the PS state associated with a given time and based on the measurement set corresponding to that moment of time.…”
Section: State Estimationmentioning
confidence: 99%