2019
DOI: 10.1016/j.applthermaleng.2019.02.135
|View full text |Cite
|
Sign up to set email alerts
|

Summer study on thermal performance of an exhausting airflow window in evaporatively-cooled buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(13 citation statements)
references
References 20 publications
0
12
0
Order By: Relevance
“…The results of the study mentioned that the type of window affects the airflow. The determination of the window needs to be adjusted to the climate variable at a place [16], [17].…”
Section: Results S and Discussionmentioning
confidence: 99%
“…The results of the study mentioned that the type of window affects the airflow. The determination of the window needs to be adjusted to the climate variable at a place [16], [17].…”
Section: Results S and Discussionmentioning
confidence: 99%
“…In the literature there are several examples of using CFD to examine the behavior, characteristics, and energy consumption and comfort status of a DSF (Pappas and Zhai 2008, Safer et al 2005, Ye et al 1999. Studies on DSF microclimatic thermal comfort are mostly limited to colder and warmer climatic conditions (Alberto et al 2017, Khalvati and Omidvar 2019, Yang et al 2020, Saroglou et al 2020, Guardo et al 2009). However, the use of multiple or double skin facades in hot summer continental climates is not well documented.…”
Section: Athens Journal Of Technology and Engineeringmentioning
confidence: 99%
“…The radiative heat transfer coefficients between surfaces and indoors and outdoors are calculated as follows [9] : (9) (10) In Equation ( 7), T sky is the sky temperature given by [9] : (11) Also, T mr in Equation ( 8) is the mean radiant temperature of surfaces surrounding the interior glass surface, which is assumed to be equal to indoor air temperature [15] . 1 and 3 are the total of the long-wave radiative heat exchanges between channel-side surfaces of the interested glass pane and the channel-side surfaces of the other zones.…”
Section: Figure 2 Schematic Of the Ventilated Windowmentioning
confidence: 99%
“…While most of the researchers working on the ventilated window focused on evaluating thermal performance and energy efficiency [7][8][9][10][11][12] , The IAQ and energy consumption analysis has been the subject of limited studies. Gosselin and Chen [6] carried out experimentally validated computational fluid dynamics (CFD) simulations on a proposed dual airflow window to optimize the window design.…”
Section: Introductionmentioning
confidence: 99%