2014
DOI: 10.1016/j.gaitpost.2014.02.001
|View full text |Cite
|
Sign up to set email alerts
|

Summary measures for clinical gait analysis: A literature review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
106
0
4

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
4
2

Relationship

0
10

Authors

Journals

citations
Cited by 225 publications
(121 citation statements)
references
References 30 publications
(54 reference statements)
1
106
0
4
Order By: Relevance
“…Therefore, a dimensionless database could be built so as a set of dimensionless mechanical parameters would correspond to a Modela-w. Although the advantages of using database as reference have already been shown [21,25], a dimensionless database removes anthropometric individual characteristics on referenced parameters and would allow to i) compare species [26] and to ii) detect pathology among elderly [23] and young [27] by using deviation indexes [28]. Given that the dimensionless database would gather bio-markers of healthy walking (kinematic and dynamic), a relevant dimensionless deviation index could be proposed to detect a difference due to fitness, pathology, ageing, etc.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, a dimensionless database could be built so as a set of dimensionless mechanical parameters would correspond to a Modela-w. Although the advantages of using database as reference have already been shown [21,25], a dimensionless database removes anthropometric individual characteristics on referenced parameters and would allow to i) compare species [26] and to ii) detect pathology among elderly [23] and young [27] by using deviation indexes [28]. Given that the dimensionless database would gather bio-markers of healthy walking (kinematic and dynamic), a relevant dimensionless deviation index could be proposed to detect a difference due to fitness, pathology, ageing, etc.…”
Section: Discussionmentioning
confidence: 99%
“…Realistically any number of possible micro gait outcomes can be quantified due to the range of mathematical permutations which could be applied to wearable data, which has hindered clinical use [46]. In general, micro outcomes can be classed as spatio-temporal and frequency-based (e.g.…”
Section: Activity Recognition: Macro and Micro Gaitmentioning
confidence: 99%
“…Healthcare professionals such as physiotherapists and biomedical engineers perform 3DGA. The examination provides a large amount of complex and interdependent data, which have led to the development of indices that can describe the quality of the gait pattern in a single score [2]. The summary measures most commonly used are the Gait Deviation Index (GDI) [3] and the Gait Profile Score (GPS) [4], which both provide a single score of the quality of the patient's kinematics during gait.…”
Section: Introductionmentioning
confidence: 99%