2014
DOI: 10.1016/j.electacta.2014.10.084
|View full text |Cite
|
Sign up to set email alerts
|

Sulfonated polyimide membranes with different non-sulfonated diamines for vanadium redox battery applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
24
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 65 publications
(27 citation statements)
references
References 29 publications
3
24
0
Order By: Relevance
“…There are three weight loss stages for both membranes. The 1 st mass loss changed from 100 to 150 C is ascribed to remove little moisture absorbed by -SO 3 H. The 2nd is attributed to degradation of -SO 3 H ranged from 300 to 450 C, which is agreement with what was reported elsewhere [16,17,47,48]. The 3rd stage is related to decomposition of the polymer backbone.…”
Section: Thermal Stability and Mechanical Performancesupporting
confidence: 89%
See 2 more Smart Citations
“…There are three weight loss stages for both membranes. The 1 st mass loss changed from 100 to 150 C is ascribed to remove little moisture absorbed by -SO 3 H. The 2nd is attributed to degradation of -SO 3 H ranged from 300 to 450 C, which is agreement with what was reported elsewhere [16,17,47,48]. The 3rd stage is related to decomposition of the polymer backbone.…”
Section: Thermal Stability and Mechanical Performancesupporting
confidence: 89%
“…Obviously, the positive electrolyte (VO 2+ /VO 2 + ) is more oxidizing than negative electrolyte (V 2+ /V 3+ ), causing both bSPI-8 and SPI membranes' surfaces in contact with positive electrolytes to be more seriously destructed. Similar experimental phenomenon was also reported in another study [17]. In addition, the cross-sections of initial membrane and after cycling charge-discharge testing of bSPI-8 membrane are depicted in Fig.…”
Section: Structure and Morphology Analysissupporting
confidence: 74%
See 1 more Smart Citation
“…The costs of Fb‐SPI membranes are estimated to be approximately $170–220 m −2 , which is far lower than the price of Nafion membrane $600–800 m −2 . For comparison, l‐SPI membrane (DS: 50 %) was also synthesized and prepared according to the procedures reported in literature …”
Section: Methodsmentioning
confidence: 99%
“…9,10 Furthermore, SPI is sufficiently thermally stable to be used in VRFBs. In our earlier work, a series of proton-conductive membranes based on SPI for VRFB applications were developed 11 and as-prepared SPI membranes showed high proton selectivity, low vanadium ion permeability and good single VRFB performance. However, pristine SPI membranes also exhibit lower antioxidant ability compared with Nafion membranes.…”
Section: Introductionmentioning